34 Monitor ISM/xL™ Hardware Guide
22-0375 rev1.1
Multi-Door Controller
12
3
4
56
78
9
10 11
12
13
14
15 16 17
18 19 20
(-)(+)(-)(+)(-)(+)(-)(+)
(-)(+)
T
B
2
Not
Used
AC AC
(+)
(-)(+)(-)
DC
BAT
Power Links for Mag Locks
Door 5
Lock
Door 6
Lock
Door 7
Lock
Door 8
Lock
12
3
4
567891011
12
13
14
15 16 17 18 19 20 21 22
(-)(+)(-)(+)(-)(+)(-)(+)(-)(+)
Power Links for Door Strikes (Momentary Power)
(+) pass-through
A
B
T
B
1
AC AC
(+)
(-)(+)(-)
DC
BAT
PS for Door
Strikes
Module Bus
Connections
Door 1
Lock
Door 2
Lock
Door 3
Lock
Door 4
Lock
© 2003 CSG Security Inc. / Sécurité CSG Inc. 452-9151 v1.2 (Oct 2003)
(-)(+)
120-8520
(A) In and Out
(B) In and Out
(-) In and Out
120-8520
Door1
Door2
Door3
Door4
Door5
Door6
Door7
Door8
The Multi-Door Controller is pre-wired to power 8 Doors with Door
Strikes.
If a door requires mag lock power instead, remove the link for the
door number strike and jump the previous door’s strike power to
the next doors’.
Example: Door 3 has a mag lock. Remove the pre-wired jumper
between door 3 and 4 and move the connection from 3 to 4 to
continue supplying power to the remaining doors.
Bypass
Remove
Door
Controller 1
Door
Controller 2
Door1
Door2
Door3
Door4
Door5
Door6
Door7
Door8
Door
Controller 3
Door
Controller 4
Continued at Power Links for Mag Locks TB2
Example: Door 3 has a mag lock. After its strike
power jumper has been bypassed, add a jumper
for its positive mag power. Supply mag power to
each door using a mag, in the same way.
Door
Lock
Coil
+
+
-
Install diode or MOV close to the lock [DC
strike, or mag. lock w/o rev. coils: Use
Diode. Otherwise, install 27 V M.O.V.]
-
Door Lock Detail
Backup Batteries
Each power supply requires a separate battery. These may need to be smaller than 7 Ah
to fit into the cabinet. Exception: If you must share a battery between 2 P/Ss, insert a
diode in the BAT (+) connection to the second PS.
Battery
P/SP/S
+
+
+
-
-
-
Ensure each cabinet is connected to
a locally-approved earth ground
using at least 18 AWG wire.
Do not connect anything else to the
earth ground.
Connect the Module Bus cable
shields together inside each cabinet
and only connect the shield to earth
ground at the ISM panel.
Grounding
Jumper
Strike and mag lock connections are pre-wired between the door
controller boards and the two large terminal strips near the bottom
of the cabinet. Module Bus connections are provided as well.
Other connections (such as reader cables, door contacts, etc.)
connect directly to the door controller boards.
For door-strike and mag lock instructions, refer to the "Power
Links" sections.
Multi - Door Controller General Wiring
Door
Controller 1
Door
Controller 2
Door
Controller 3
Door
Controller 4
Door 1
Door 2
Door 3
Door 4
Door 5
Door 6
Door 7
Door 8
Multi-Door Controller Cabinet
TB1
TB2
The 4-6 door and 4-8 door upgrade
kits include door-controller board(s),
a power supply, and mounting
hardware.
The wiring harness is pre-wired to
power the additional door controller
board(s) from the second P/S.
Upgrading the
Door Capacity
AC AC
(+)
(-)(+)(-)
DC
BAT
`
Add PS for Mag locks
AC AC
(+)
(-)(+)(-)
DC
BAT
Required for 8-door units.
Included in 4-8 door upgrade kits.)
`
Add PS for Door
Controllers 3 & 4
120-8520
(Maintained Power)
PS for Door
Controllers 1 & 2
The default door strike wiring is for
"Fail-Secure" (powered = unlocked).
For "Fail-Safe" door strikes
(powered = locked), connect to the
large terminal strips as usual, AND at
each applicable Door Controller Unlock
Relay, move the N/O wire to N/C
terminal:
Fail-Safe Door Strikes
N/C
Com
N/O
1 2 3
X
X
Multi-Door
Controller
The system shall not be installed in the
fail secure mode unless permitted by the
local authority having jurisdiction and
shall not interfere with the operation of
panic hardware.
2 Door Controller Ratings
Input: 12VDC, 840mA
Output: 12VDC, 40mA (Auxiliary power)
12VDC, 500mA or 5VDC, 240mA
(Reader power)
For use in 2 Door Controller models:
950-9011, 950-9012, 950-9013, 950-9014
See Two Door Controller Installation
Instructions: 22-0353
For UL Installations
16V, 40VA
16V, 40VA 16V, 40VA
16V, 40VA
120-8520