Interlogix NX-8V2 REV H Installation Manual Manual de usuario

Busca en linea o descarga Manual de usuario para Panel De Control Interlogix NX-8V2 REV H Installation Manual. Interlogix NX-8V2 REV H Installation Manual User Manual Manual de usuario

  • Descarga
  • Añadir a mis manuales
  • Imprimir

Indice de contenidos

Pagina 1 - Installation Manual

P/N I-NX8V2-IM • REV H • ISS NOV12 NX-8V2 Control Panel Installation Manual

Pagina 2

Chapter 1: Reporting codes 6 NX-8V2 Control Panel Installation Manual Module list Table 3 below shows some of the modules that are compatible with t

Pagina 3 - Content

Chapter 1: Reporting codes NX-8V2 Control Panel Installation Manual 7 Part number Description NX-1324E 24-zone LED door design keypad. NX-1448E 48

Pagina 5 - Introduction

NX-8V2 Control Panel Installation Manual 9 Chapter 2 Programming Summary This chapter provides basic programming instructions and a description of

Pagina 6 - Product overview

Chapter 2: Reporting codes 10 NX-8V2 Control Panel Installation Manual Location 44 - Duress code 37 Locations 45 to 50 - Auxiliary outputs progra

Pagina 7 - Board installation

Chapter 2: Reporting codes NX-8V2 Control Panel Installation Manual 11 LED keypad programming This section describes how to program the address of

Pagina 8 - Chapter 1: Reporting codes

Chapter 2: Reporting codes 12 NX-8V2 Control Panel Installation Manual LED Keypad feature enabled 8 Enable multiple partition viewing. Enable tempor

Pagina 9 - Terminal descriptions

Chapter 2: Reporting codes NX-8V2 Control Panel Installation Manual 13 System clock To set the system clock: 1. Enter *, 9, 7, master code. The Se

Pagina 10 - Module list

Chapter 2: Reporting codes 14 NX-8V2 Control Panel Installation Manual assigned authority levels to all user numbers, or you can press # to exit a

Pagina 11 - Chapter 1: Reporting codes

Chapter 2: Reporting codes NX-8V2 Control Panel Installation Manual 15 To enter program mode: 1. Press *, 8. The five function LEDs (Stay, Chime,

Pagina 12

Copyright © 2012 UTC Fire & Security Americas Corporation, Inc. Interlogix is part of UTC Climate Controls & Security, a unit of United

Pagina 13 - Programming

Chapter 2: Reporting codes 16 NX-8V2 Control Panel Installation Manual You are now ready to enter another programming location. If you attempt to p

Pagina 14 - Chapter 2: Reporting codes

Chapter 2: Reporting codes NX-8V2 Control Panel Installation Manual 17 Feature selection data Feature selection data displays the current condition

Pagina 15 - LED keypad programming

Chapter 2: Reporting codes 18 NX-8V2 Control Panel Installation Manual a siren or bell is attached to the NX-8V2, it sound for about 1 second. If the

Pagina 16 - Keypad number and partition

Chapter 2: Reporting codes NX-8V2 Control Panel Installation Manual 19 Programming locations This section describes all the programming options for

Pagina 17 - User authority level

Chapter 2: Reporting codes 20 NX-8V2 Control Panel Installation Manual Caution: A call-waiting cancel on a non call-waiting line prevents successful

Pagina 18 - Control panel programming

Chapter 2: Reporting codes NX-8V2 Control Panel Installation Manual 21 Data Format Description 11 4+2 express Two-digit event code DTMF transmis

Pagina 19 - Chapter 2: Reporting codes

Chapter 2: Reporting codes 22 NX-8V2 Control Panel Installation Manual Location 4 - Phone 1 events reported Location 4 has two segments of feature se

Pagina 20 - Programming data types

Chapter 2: Reporting codes NX-8V2 Control Panel Installation Manual 23 • Enter 11 for a *, and 12 for a #. • Enter 14 to indicate the end of the

Pagina 21 - Loading factory defaults

Chapter 2: Reporting codes 24 NX-8V2 Control Panel Installation Manual • If you want dual or split reporting and the split is based on the event ty

Pagina 22

Chapter 2: Reporting codes NX-8V2 Control Panel Installation Manual 25 Location 13 - Phone 3 account code Location 13 has six segments of numerical

Pagina 23 - Programming locations

NX-8V2 Control Panel Installation Manual i Content Important information ii Chapter 1 Introduction 1 Product overview 2 Board installation

Pagina 24

Chapter 2: Reporting codes 26 NX-8V2 Control Panel Installation Manual Segment 1 1. Alarms and alarm restores. 2. Opening and closings. 3. Zone byp

Pagina 25

Chapter 2: Reporting codes NX-8V2 Control Panel Installation Manual 27 Segment 1 1. On for 1800 Hz transmit; off for 1900 Hz. 2. On for 2300 Hz

Pagina 26

Chapter 2: Reporting codes 28 NX-8V2 Control Panel Installation Manual Segment 1 1. On enables two call answering machine defeat. 2. On enables t

Pagina 27

Chapter 2: Reporting codes NX-8V2 Control Panel Installation Manual 29 Segment 1 1. On enables quick arm. 2. On enables re-exit. 3. On enables au

Pagina 28

Chapter 2: Reporting codes 30 NX-8V2 Control Panel Installation Manual Segment 3 - Entry time 2. Entry time used when a delay 2 zone type initiates

Pagina 29

Chapter 2: Reporting codes NX-8V2 Control Panel Installation Manual 31 Zone type Description 10. 24-hour silent supervised Creates an instant sile

Pagina 30

Chapter 2: Reporting codes 32 NX-8V2 Control Panel Installation Manual Zone type Description 24. Manual fire Illuminates the Fire LED and sounds the

Pagina 31

Chapter 2: Reporting codes NX-8V2 Control Panel Installation Manual 33 Location 28 Zones 9 to 16 partition Location 28 has eight segments of featu

Pagina 32

Chapter 2: Reporting codes 34 NX-8V2 Control Panel Installation Manual Location 37 - Siren and system supervision Location 37 has seven segments of f

Pagina 33

Chapter 2: Reporting codes NX-8V2 Control Panel Installation Manual 35 3. On disables on board 8 zones. 4. On allows two trips on same cross zone t

Pagina 34

ii NX-8V2 Control Panel Installation Manual Important information This is the NX-8V2 Control Panel Installation Manual. This document includes an

Pagina 35

Chapter 2: Reporting codes 36 NX-8V2 Control Panel Installation Manual Segment 2 - AC fail report delay in minutes, 0 to 255 (0 = no delay). Default

Pagina 36

Chapter 2: Reporting codes NX-8V2 Control Panel Installation Manual 37 Location 43 - Go to program code and authorization Location 43 has two segme

Pagina 37

Chapter 2: Reporting codes 38 NX-8V2 Control Panel Installation Manual Location 46 - Auxiliary outputs 1 to 4 special timing Location 46 has four seg

Pagina 38

Chapter 2: Reporting codes NX-8V2 Control Panel Installation Manual 39 Location 50 - Auxiliary output 4 event and times Location 50 has two segment

Pagina 39 - Location 40 - System timers

Chapter 2: Reporting codes 40 NX-8V2 Control Panel Installation Manual 42 = Siren tamper 43 = Any open 44 = Any short 45 = Any fault (short on nonfir

Pagina 40

Chapter 2: Reporting codes NX-8V2 Control Panel Installation Manual 41 Locations 52 to 55 - Times and days Location 52 - Opening/automatic disarm t

Pagina 41 - Location 44 - Duress code

Chapter 2: Reporting codes 42 NX-8V2 Control Panel Installation Manual Location 55 - Days of week each partition will automatically arm Location 55 h

Pagina 42

Chapter 2: Reporting codes NX-8V2 Control Panel Installation Manual 43 Location 56 Restore communicator code Program the event code for any zone

Pagina 43

Chapter 2: Reporting codes 44 NX-8V2 Control Panel Installation Manual Location 72 Telephone line cut/restore communicator code Program the digits

Pagina 44

Chapter 2: Reporting codes NX-8V2 Control Panel Installation Manual 45 day programmed. The default is to begin daylight saving time on the second S

Pagina 45

NX-8V2 Control Panel Installation Manual 1 Chapter 1 Introduction Summary This chapter provides an overview of your NX-8V2 Control Panel, including

Pagina 46

Chapter 2: Reporting codes 46 NX-8V2 Control Panel Installation Manual Locations 88 Partition 1 account code Location 88 has six segments of numeric

Pagina 47

Chapter 2: Reporting codes NX-8V2 Control Panel Installation Manual 47 4. There are two separate entry/exit times (Location 24).

Pagina 48

Chapter 2: Reporting codes 48 NX-8V2 Control Panel Installation Manual Location 98 Partition 5 account code Location 98 has six segments of numeric

Pagina 49

Chapter 2: Reporting codes NX-8V2 Control Panel Installation Manual 49 segment immediately after the last digit of the account number. If the acco

Pagina 50

Chapter 2: Reporting codes 50 NX-8V2 Control Panel Installation Manual Segment 2 1. On if zone type beeps the keypad for alarm. 2. On if zone type s

Pagina 51

Chapter 2: Reporting codes NX-8V2 Control Panel Installation Manual 51 Location Zone type Description Default 119 5 Feature selection 457, 125, 56

Pagina 52

Chapter 2: Reporting codes 52 NX-8V2 Control Panel Installation Manual Location Zone type Description Default 152 22 Alarm code 20 153 22 Feature se

Pagina 53

NX-8V2 Control Panel Installation Manual 53 Chapter 3 Troubleshooting Summary This chapter provides product specifications and information to help

Pagina 54

Chapter 3: Reporting codes 54 NX-8V2 Control Panel Installation Manual General diagnosis Trouble conditions are diagnosed by viewing the detailed in

Pagina 55

Chapter 3: Reporting codes NX-8V2 Control Panel Installation Manual 55 3. The backup battery is shorted internally or is defective. Remove the ba

Pagina 56

Chapter 1: Reporting codes 2 NX-8V2 Control Panel Installation Manual Product overview The NX-8V2 Control Panel is a residential security and alarm s

Pagina 57 - Troubleshooting

Chapter 3: Reporting codes 56 NX-8V2 Control Panel Installation Manual The siren does not work. The control panel has a built in siren driver. If the

Pagina 58 - Trouble conditions

Chapter 3: Reporting codes NX-8V2 Control Panel Installation Manual 57 Phone or power voltage Value Battery to battery 13.5 VDC Table 11: Zone volt

Pagina 59 - Chapter 3: Reporting codes

Chapter 3: Reporting codes 58 NX-8V2 Control Panel Installation Manual LED keypad Current draw Without sounder Dimensions 130 mA max. 55 m

Pagina 60 - Voltage tables

NX-8V2 Control Panel Installation Manual 59 Appendix A Reporting codes Summary This appendix provides tables for various events and transmissions as

Pagina 61 - Specification

Appendix A: Reporting codes 60 NX-8V2 Control Panel Installation Manual Reporting fixed codes in Contact ID and SIA The NX-8V2 can report SIA level 1

Pagina 62 - Chapter 3: Reporting codes

Appendix A: Reporting codes NX-8V2 Control Panel Installation Manual 61 Contact ID event SIA Description 120 PA Keypad panic (audible) a 121 HA Key

Pagina 63 - Reporting codes

Appendix A: Reporting codes 62 NX-8V2 Control Panel Installation Manual Reporting zone codes in Contact ID and SIA The NX-8V2 has the ability to repo

Pagina 64 - Appendix A: Reporting codes

Appendix A: Reporting codes NX-8V2 Control Panel Installation Manual 63 Reporting Ademco Contact ID transmissions The NX-8V2 has the ability to rep

Pagina 65

Appendix A: Reporting codes 64 NX-8V2 Control Panel Installation Manual Device numbers for reporting expander troubles The following tables list the

Pagina 66 - (Locations 110 to 169)

Appendix A: Reporting codes NX-8V2 Control Panel Installation Manual 65 Device Name Number 570E/580E Switch 3 on Device address 25 Switch 1 and 3

Pagina 67

Chapter 1: Reporting codes NX-8V2 Control Panel Installation Manual 3 Board installation Inside the metal enclosure, there are slots for board ins

Pagina 68

Appendix A: Reporting codes 66 NX-8V2 Control Panel Installation Manual Zone/user ID = Hex digit Zone/user ID = Hex digit Zone/ID = Hex digit 10 = A

Pagina 69

NX-8V2 Control Panel Installation Manual 67 Appendix B Programming worksheet Summary This appendix provides a programming worksheet that shows locat

Pagina 70

Appendix B: Reporting codes 68 NX-8V2 Control Panel Installation Manual Programming worksheet Use the following worksheet to check location defaults

Pagina 71 - Programming worksheet

Appendix B: Reporting codes NX-8V2 Control Panel Installation Manual 69 Loc. Description Default Setting 13 Phone 3 account code 10, 10, 10, 10, 10

Pagina 72

Appendix B: Reporting codes 70 NX-8V2 Control Panel Installation Manual Loc. Description Default Setting Segment 3 1 = Open/close 2 = Bypass 3 = Rest

Pagina 73

Appendix B: Reporting codes NX-8V2 Control Panel Installation Manual 71 Loc. Description Default Setting 34 Zones 33 to 40 partitions Segment 1 =

Pagina 74

Appendix B: Reporting codes 72 NX-8V2 Control Panel Installation Manual Loc. Description Default Setting 39 Keypad sounder control Segment 1 1 = Key

Pagina 75

Appendix B: Reporting codes NX-8V2 Control Panel Installation Manual 73 Loc. Description Default Setting 43 Go to program code and authorization S

Pagina 76

Appendix B: Reporting codes 74 NX-8V2 Control Panel Installation Manual Loc. Description Default Setting Segment 1 = Event number for output 3 2 (24-

Pagina 77

Appendix B: Reporting codes NX-8V2 Control Panel Installation Manual 75 Loc. Description Default Setting 1 = Sunday 1 1 1 1 1 1 1 1 2 = Monday 2 2

Pagina 78

Chapter 1: Reporting codes 4 NX-8V2 Control Panel Installation Manual Figure 3: NX-8V2 wiring diagram

Pagina 79

Appendix B: Reporting codes 76 NX-8V2 Control Panel Installation Manual Loc. Description Default Setting Segment 8 = Partition 8 tamper code 0 59 Tr

Pagina 80

Appendix B: Reporting codes NX-8V2 Control Panel Installation Manual 77 Loc. Description Default Setting 68 AC fail/restore communicator code 0,

Pagina 81

Appendix B: Reporting codes 78 NX-8V2 Control Panel Installation Manual Loc. Description Default Setting 86 Reserved 87 Reserved 88 Partition 1 accou

Pagina 82

Appendix B: Reporting codes NX-8V2 Control Panel Installation Manual 79 Loc. Description Default Setting Segment 3 1 = Open/close 2 = Bypass 3 = Re

Pagina 83

Appendix B: Reporting codes 80 NX-8V2 Control Panel Installation Manual Loc. Description Default Setting 99 Partition 5 feature and reporting selec

Pagina 84

Appendix B: Reporting codes NX-8V2 Control Panel Installation Manual 81 Loc. Description Default Setting 103 Partition 6 entry and exit times Segme

Pagina 85

Appendix B: Reporting codes 82 NX-8V2 Control Panel Installation Manual Loc. Description Default Setting Segment 1 1 = Quick arm 2 = Re-exit 3 = Auto

Pagina 86

Appendix B: Reporting codes NX-8V2 Control Panel Installation Manual 83 Loc. Description Default Setting Segment 3 1 = Fast loop response 2 = Doubl

Pagina 87

Appendix B: Reporting codes 84 NX-8V2 Control Panel Installation Manual Loc. Description Default Setting 139 Zone type 15 feature select 457, 1256,

Pagina 88

Appendix B: Reporting codes NX-8V2 Control Panel Installation Manual 85 Loc. Description Default Setting 206 Days of the w eek auto disarming w ill

Pagina 89

Chapter 1: Reporting codes NX-8V2 Control Panel Installation Manual 5 Terminal descriptions Table 2 below describes the terminals shown in the wir

Pagina 91 - Glossary

NX-8V2 Control Panel Installation Manual 87 Glossary Abort In enabled, the NX-8V2 waits the number of seconds programmed in Location 40 prior

Pagina 92

Glossary 88 NX-8V2 Control Panel Installation Manual Automatic cancel/abort If enabled, the cancel and/or abort features are automatic (pressing t

Pagina 93 - Glossary

Glossary NX-8V2 Control Panel Installation Manual 89 Dual/split/multiple reports The NX-8V2 sends communication reports to three different phone

Pagina 94

Glossary 90 NX-8V2 Control Panel Installation Manual Fail to communicate The NX-8V2 illuminates the Service LED if a report fails to reach the ce

Pagina 95

Glossary NX-8V2 Control Panel Installation Manual 91 Manual test If programmed, the NX-8V2 performs a bell and/or communicator test when *, 4, 4

Pagina 96

Glossary 92 NX-8V2 Control Panel Installation Manual Swinger shutdown This feature allows a zone or zones to be automatically bypassed after a spec

Pagina 97

Glossary NX-8V2 Control Panel Installation Manual 93 Zone activity monitor This feature sends a report to the central station when a particular

Comentarios a estos manuales

Sin comentarios