Interlogix Concord 4 REV J Installation Manual Manual de usuario Pagina 96

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 153
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 95
Chapter 3: Programming
90 Concord 4 Installation Manual
Attach schedules to events menu
This section describes how to link the system events to time schedules.
Latchkey reports
Shortcut:
060nn (opening),
061nn (closing), where
nn is schedule number
Default: Off
This setting lets you attach the latchkey opening report feature and the
latchkey closing report feature to time schedules.
To attach a schedule to latchkey opening or latchkey closing:
1. Press A or B until the display shows ATTACH SCHEDULES TO
EVENTS.
2. Press # then A or B until the display shows LATCHKEY OPENING
or LATCHKEY CLOSING.
3. Press # and the display shows SCHEDULE 00 OFF/ON (current
setting). If you want a different schedule, press A or B until the desired
schedule appears.
4. Press 1 (off) or 2 (on). The display flashes the entered selection.
Press # and the display shows the new setting for the selected
schedule.
Exception reports
Shortcut:
062nn (opening),
063nn (closing), where
nn is schedule number
Default: Off
This setting lets you attach the exception opening report feature and the
exception closing report feature to time schedules.
To attach a schedule to exception opening or exception closing:
1. Press A or B until the display shows ATTACH SCHEDULES TO
EVENTS.
2. Press # then A or B until the display shows EXCEPTION
OPENING OR EXCEPTION CLOSING.
3. Press # and the display shows SCHEDULE 00 OFF/ON (current
setting). If you want a different schedule, press A or B until the schedule
appears.
4. Press 1 (off) or 2 (on). The display flashes the entered selection.
Press # and the display shows the new setting for the selected
schedule.
Vista de pagina 95
1 2 ... 91 92 93 94 95 96 97 98 99 100 101 ... 152 153

Comentarios a estos manuales

Sin comentarios