Concord 4 Installation Manual P/N 466-2182 • REV J • NOV12

Pagina 2

Chapter 1: Introduction 4 Concord 4 Installation Manual SnapCards The following SnapCards expand the system as described: 8Z input Snapcard: Provi

Pagina 3 - Content

Chapter 3: Programming 94 Concord 4 Installation Manual A Downloader phone number should be programmed and the user-programmable option Downloading m

Pagina 4

Concord 4 Installation Manual 95 Chapter 4 Testing and troubleshooting Summary This chapter provides information to help you test and troubleshoot

Pagina 5 - Important information

Chapter 4: Testing and troubleshooting 96 Concord 4 Installation Manual Testing the system Before testing, we recommend that you close the panel cabi

Pagina 6

Chapter 4: Testing and troubleshooting Concord 4 Installation Manual 97 Command System response * (STATUS) Indicates current system status 7, 1 Tur

Pagina 7 - Introduction

Chapter 4: Testing and troubleshooting 98 Concord 4 Installation Manual 4. Press the Status button when you think all zones/sensors are tested. T

Pagina 8 - Planning the installation

Chapter 4: Testing and troubleshooting Concord 4 Installation Manual 99 3. If the display continues to show PHONE TEST for 90 seconds or more, ent

Pagina 9 - SuperBus 2000 bus devices

Chapter 4: Testing and troubleshooting 100 Concord 4 Installation Manual Codes System event 333 System armed to AWAY 555 Phone/sensor test 888 Syst

Pagina 10 - Chapter 1: Introduction

Chapter 4: Testing and troubleshooting Concord 4 Installation Manual 101 4. Verify that each output responds according to the programmed configura

Pagina 11 - Installation

Chapter 4: Testing and troubleshooting 102 Concord 4 Installation Manual To test the energy saver module: 1. Press *, * to display the system status

Pagina 12 - Installation overview

Chapter 4: Testing and troubleshooting Concord 4 Installation Manual 103 2. Press and release the 1 and 2 buttons together repeatedly, until the

Pagina 13 - Chapter 2: Installation

Concord 4 Installation Manual 5 Chapter 2 Installation Summary This chapter provides information on locating and installing the panel and system c

Pagina 14 - Chapter 2: Installation

Chapter 4: Testing and troubleshooting 104 Concord 4 Installation Manual 4. The central station operator waits for the alarm to be reported and ini

Pagina 15

Chapter 4: Testing and troubleshooting Concord 4 Installation Manual 105

Pagina 16 - Mounting the panel

Chapter 4: Testing and troubleshooting 106 Concord 4 Installation Manual Troubleshooting This section provides information to help you diagnose and s

Pagina 17 - Grounding the panel

Chapter 4: Testing and troubleshooting Concord 4 Installation Manual 107 No incoming AC voltage at panel terminals 1 and 2. 1. Unplug the AC pow

Pagina 18 - Antenna shrouds

Chapter 4: Testing and troubleshooting 108 Concord 4 Installation Manual • Check that the transformer is supplying AC to the panel. WARNING: Be car

Pagina 19 - Optional SnapCards

Chapter 4: Testing and troubleshooting Concord 4 Installation Manual 109 • The installer code is being used to disarm the system. The system is de

Pagina 20 - Panel terminals

Chapter 4: Testing and troubleshooting 110 Concord 4 Installation Manual The negative red lead or (RING) wires must connect to terminal 28 on the b

Pagina 21 - Smoke detectors

Chapter 4: Testing and troubleshooting Concord 4 Installation Manual 111 • Touchpad is not connected to panel bus terminals or is wired incorre

Pagina 22

Chapter 4: Testing and troubleshooting 112 Concord 4 Installation Manual Hardwired zone issues System doesn’t go into alarm when zone is tripped. •

Pagina 23 - Four-wire smoke detectors

Chapter 4: Testing and troubleshooting Concord 4 Installation Manual 113 Touchpad indicates [sensor #] supervisory. • Use an RF Sniffer (60-401) t

Pagina 24 - Speakers and sirens

Chapter 2: Installation 6 Concord 4 Installation Manual Installation overview Before starting the installation, plan your system layout and progra

Pagina 25 - Not used

Chapter 4: Testing and troubleshooting 114 Concord 4 Installation Manual • Check RJ31X jack wiring and TELCO block wiring. Replace RJ31X jack if nec

Pagina 26 - To zone input

Chapter 4: Testing and troubleshooting Concord 4 Installation Manual 115 The module room temperature setting has not been adjusted or was adjusted

Pagina 28 - SuperBus 2000 modules

Concord 4 Installation Manual 117 Appendix A System planning sheets Summary This appendix provides various system planning sheets for the Concord 4

Pagina 29 - GND +12V A BUS B

Appendix A: System planning sheets 118 Concord 4 Installation Manual Customer information Table 19: Customer information Customer name Address Ci

Pagina 30

Appendix A: System planning sheets Concord 4 Installation Manual 119 Part number Description Quantity 60-457 Dual button panic sensor 60-578 Water

Pagina 31

Appendix A: System planning sheets 120 Concord 4 Installation Manual Part number Description Quantity mA (max.) Subtotal 60-804 2x20 VFD alphanumeric

Pagina 32 - Hardwired interior

Appendix A: System planning sheets Concord 4 Installation Manual 121 Zone and sensor assignments Table 22: Zone and sensor assignments No. RF zone

Pagina 33

Appendix A: System planning sheets 122 Concord 4 Installation Manual No. RF zone Module bus ID number Module input number Group Partition Zone/sensor

Pagina 34 - RJ31X phone jack

Appendix A: System planning sheets Concord 4 Installation Manual 123 No. RF zone Module bus ID number Module input number Group Partition Zone/sens

Pagina 35

Chapter 2: Installation Concord 4 Installation Manual 7 Figure 1: Panel and component locations on a wall Total system power and wire length guid

Pagina 36 - AC power transformer

Appendix A: System planning sheets 124 Concord 4 Installation Manual No. RF zone Module bus ID number Module input number Group Partition Zone/sensor

Pagina 37 - Power up

Appendix A: System planning sheets Concord 4 Installation Manual 125 Setting reference (default) Shortcut number Setting Bypass reports (Off) 060

Pagina 38

Appendix A: System planning sheets 126 Concord 4 Installation Manual Setting reference (default) Shortcut number Setting Global fire (Off) 0703 Gr

Pagina 39 - Programming

Appendix A: System planning sheets Concord 4 Installation Manual 127 Setting reference (default) Shortcut number Setting Opening reports (Off) 06

Pagina 40 - Overview

Appendix A: System planning sheets 128 Concord 4 Installation Manual Setting reference (default) Shortcut number Setting SnapCard output 1 (01400

Pagina 41 - Programming touchpad

Concord 4 Installation Manual 129 Appendix B Reference tables Summary This appendix provides reference tables and specifications. Content Error! Bo

Pagina 42 - Quick programming mode

Appendix B: Reference tables 130 Concord 4 Installation Manual Sensor group characteristics Table 24 below shows what the sensors on your Concord 4 s

Pagina 43 - Tier 1 programming menus

Appendix B: Reference tables Concord 4 Installation Manual 131 # Name Application Alarm Delay Restoral Supervisory CS Report Chime (Level) Activ

Pagina 44 - DEMO KIT MODE OFF/ON (new

Appendix B: Reference tables 132 Concord 4 Installation Manual # Name Application Alarm Delay Restoral Supervisory CS Report Chime (Level) Active

Pagina 45 - Chapter 3: Programming

Appendix B: Reference tables Concord 4 Installation Manual 133 Cross-zoning Cross-zoning (two-trip) refers to two different group 18 sensors that m

Pagina 46 - Tier 2 programming menus

Chapter 2: Installation 8 Concord 4 Installation Manual Table 4 below describes the maximum wire length allowed between compatible devices and the p

Pagina 47

Appendix B: Reference tables 134 Concord 4 Installation Manual Sensor text Table 25 below provides sensor text with the applicable item number. Tabl

Pagina 48

Appendix B: Reference tables Concord 4 Installation Manual 135 Item # Sensor text Item # Sensor text Item # Sensor text Item # Sensor text 029 Cabi

Pagina 49

Appendix B: Reference tables 136 Concord 4 Installation Manual System event triggers Table 26 below describes the system event triggers. Table 26: Sy

Pagina 50 - Shortcut numbers

Appendix B: Reference tables Concord 4 Installation Manual 137 System event Description Trigger number Closing report sent When a closing report h

Pagina 51 - Security menu

Appendix B: Reference tables 138 Concord 4 Installation Manual Sensor number event triggers Table 28 below describes the sensor number event trigger

Pagina 52

Appendix B: Reference tables Concord 4 Installation Manual 139 Sensor number State Trigger number State Trigger number Sensor 29 In alarm 157 Open

Pagina 53

Appendix B: Reference tables 140 Concord 4 Installation Manual Sensor number State Trigger number State Trigger number Sensor 62 In alarm 190 Open 31

Pagina 54 - PARTITION

Appendix B: Reference tables Concord 4 Installation Manual 141 Sensor number State Trigger number State Trigger number Sensor 95 In alarm 223 Open

Pagina 55

Appendix B: Reference tables 142 Concord 4 Installation Manual Feature State Trigger number Recent closing report Occurred 249 Sensor test Entered 25

Pagina 56 - Phones menu

Appendix B: Reference tables Concord 4 Installation Manual 143 Response characteristics Table 30 below describes the response characteristics. Tabl

Pagina 57 - PHONE NUMBER _

Chapter 2: Installation Concord 4 Installation Manual 9 Device Max. wire length to panel Standby mA draw Alarm mA draw SuperBus 2000 energy saver

Pagina 58 - NUMBER _

Appendix B: Reference tables 144 Concord 4 Installation Manual Response number Siren tracking Trip delay Response time 11 Yes [1] No Sustained [3]

Pagina 59

Appendix B: Reference tables Concord 4 Installation Manual 145 Specifications Power requirements Auxiliary power output Class 2, 16.5 VAC, 40 V

Pagina 61

147 Concord 4 Installation Manual

Pagina 62

Chapter 2: Installation 10 Concord 4 Installation Manual Wire type Total system wire 22-gauge, unshielded 22-gauge, shielded 4,000 ft. 3,000 ft. T

Pagina 63 - Timers menu

Chapter 2: Installation Concord 4 Installation Manual 11 5. Partially insert screws into the two top mounting hole locations, then hang the pane

Pagina 64 - NO USAGE

Chapter 2: Installation 12 Concord 4 Installation Manual Antenna shrouds Install a plastic antenna shroud (included with panel) over each antenna

Pagina 65 - Light control menu

Chapter 2: Installation Concord 4 Installation Manual 13 Optional SnapCards Use the SnapCard header on the right side of the panel (Figure 4 below)

Pagina 66 - Touchpad options menu

Copyright © 2012 UTC Fire & Security Americas Corporation, Inc. Interlogix is part of UTC Climate Controls & Security, a unit of Unite

Pagina 67 - Reporting menu

Chapter 2: Installation 14 Concord 4 Installation Manual Panel terminals Figure 5 below shows an overview of panel terminals. The following sections

Pagina 68

Chapter 2: Installation Concord 4 Installation Manual 15 Intrusion detection devices Figure 6 below shows the typical wiring for NC and NO door/win

Pagina 69

Chapter 2: Installation 16 Concord 4 Installation Manual Note: When using two-wire smoke detectors on zone 8, the two-wire smoke setting (in program

Pagina 70

Chapter 2: Installation Concord 4 Installation Manual 17 Figure 8: Polarity reversal module OUT 2+12V GNDZONE 82W-SMK Polarity reversalmodule (p

Pagina 71

Chapter 2: Installation 18 Concord 4 Installation Manual Speakers and sirens The panel provides one siren driver output for intrusion (steady), fir

Pagina 72 - Siren options menu

Chapter 2: Installation Concord 4 Installation Manual 19 Figure 10: Connecting hardwired interior speakers SPKR SPKR SPKR SPKRNot usedNot used7

Pagina 73 - Sensors menu

Chapter 2: Installation 20 Concord 4 Installation Manual Figure 11: Connecting exterior sirens Panel terminalsRedBlackOUT1 GND Output 2 Onboard outp

Pagina 74

Chapter 2: Installation Concord 4 Installation Manual 21 Interrogator 200 audio verification module A maximum of two audio veification modules (AVM

Pagina 75 - SENSOR GROUP nn

Chapter 2: Installation 22 Concord 4 Installation Manual SuperBus 2000 touchpads SuperBus 2000 touchpads may have wires or screw terminals. All use

Pagina 76

Chapter 2: Installation Concord 4 Installation Manual 23 Figure 15: Installing SuperBus 2000 modules SuperBus 2000 2-amp power supply (600-1019)

Pagina 77 - Audio verification menu

Concord 4 Installation Manual i Content Important information iii Chapter 1 Introduction 1 Planning the installation 2 SuperBus 2000 bus d

Pagina 78 - AUDIO VERIFY

Chapter 2: Installation 24 Concord 4 Installation Manual Figure 17: Wiring transceivers +12VABGND/COMPanel terminalsTransceiver terminalsGND +12V

Pagina 79 - Accessory modules menu

Chapter 2: Installation Concord 4 Installation Manual 25 of the cabinet using an optional plastic housing (part no. 60-800). Refer to the documenta

Pagina 80 - PARTITION ASSIGN n

Chapter 2: Installation 26 Concord 4 Installation Manual Figure 20: Wiring for status and alarm (or status only) messages Module terminalsHardwired

Pagina 81 - CONFIGURATION tttrr

Chapter 2: Installation Concord 4 Installation Manual 27 SuperBus 2000 8Z input and 4-relay output modules Connect the modules to the panel as show

Pagina 82

Chapter 2: Installation 28 Concord 4 Installation Manual SuperBus 2000 wireless cellular gateway Connect the SuperBus 2000 wireless cellular gateway

Pagina 83

Chapter 2: Installation Concord 4 Installation Manual 29 • For full line seizure, install an RJ31X phone jack on the premises phone line so the p

Pagina 84 - Onboard options menu

Chapter 2: Installation 30 Concord 4 Installation Manual Figure 25: Wiring an RJ31X jack and DB-8 cord BRN25 26 27 28TelcoHouseDB-8 cordRJ31X jackDea

Pagina 85

Chapter 2: Installation Concord 4 Installation Manual 31 Backup battery Use the 60-681 (12 VDC, 4.5 or 5 Ah) or 60-680 (12 VDC, 7Ah) backup battery

Pagina 86

Chapter 2: Installation 32 Concord 4 Installation Manual down onto the prongs of the plug while you are securing the transformer to the outlet box. 6

Pagina 87 - Macro keys menu

Concord 4 Installation Manual 33 Chapter 3 Programming Summary This chapter provides instructions on how to program the Concord 4 and includes desc

Pagina 88 - User programming mode

ii Concord 4 Installation Manual Troubleshooting 106 Appendix A System planning sheets 117 Customer information 118 Wireless devices 118 Ha

Pagina 89 - Time and date menu

Chapter 3: Programming 34 Concord 4 Installation Manual Overview For onsite system programming, you must have an alphanumeric touchpad. You must u

Pagina 90 - User codes menu

Chapter 3: Programming Concord 4 Installation Manual 35 Figure 27: Programming touchpad Programming touchpadProgramming touchpad

Pagina 91

Chapter 3: Programming 36 Concord 4 Installation Manual Quick programming mode Use the quick programming mode to program basic system programming wit

Pagina 92

Chapter 3: Programming Concord 4 Installation Manual 37 Tier 1 programming menus There are two basic tiers of programming menus as shown in Table

Pagina 93 - Options menu

Chapter 3: Programming 38 Concord 4 Installation Manual System programming Use this setting to access the tier 2 programming menus. (See “Tier 2

Pagina 94 - Set up schedules menu

Chapter 3: Programming Concord 4 Installation Manual 39 Partition 1 copy Default = None After programming all settings pertaining to partition 1

Pagina 95

Chapter 3: Programming 40 Concord 4 Installation Manual Tier 2 programming menus Table 10 below shows the tier 2 system programming menus. Where app

Pagina 96

Chapter 3: Programming Concord 4 Installation Manual 41 Pager 4 Phone number (01060) [None] High lvl rpts (01061) [On] Low lvl rpts (01062) [On

Pagina 97

Chapter 3: Programming 42 Concord 4 Installation Manual Reporting Global 24-hour tamper (06000) [Off] Antenna tamper (06001) [Off] Buffer contro

Pagina 98 - Energy saver menu

Chapter 3: Programming Concord 4 Installation Manual 43 Accessory modules Bus device Unit – ID (10000 to 10015) [Off] Change ID Device ID

Pagina 99 - Downloader programming

Concord 4 Installation Manual iii Important information Intended use Use this product only for the purpose it was designed for; refer to the data s

Pagina 100 - Chapter 3: Programming

Chapter 3: Programming 44 Concord 4 Installation Manual The following sections guide you through the tier 2 system programming menu items as they

Pagina 101 - Testing and

Chapter 3: Programming Concord 4 Installation Manual 45 Security menu Security - global settings Downloader code Shortcut: 0000 Default: 12345 Us

Pagina 102 - Testing the system

Chapter 3: Programming 46 Concord 4 Installation Manual Multipartition arm/disarm Shortcut: 0004 Default: Off. Partition to turn on This feature co

Pagina 103 - Zones/sensors

Chapter 3: Programming Concord 4 Installation Manual 47 Keyfob PTN Shortcut: 0006 Default: On This feature controls which partitions the selected

Pagina 104 - Phone communication

Chapter 3: Programming 48 Concord 4 Installation Manual 5. Press # and the display stops flashing. To disable keyfob PTN: 1. Enter this menu (display

Pagina 105

Chapter 3: Programming Concord 4 Installation Manual 49 Security - partition 1 to 6 settings Account number Shortcut: 0010 to 0060 Default: 0000

Pagina 106 - Outputs and sirens

Chapter 3: Programming 50 Concord 4 Installation Manual Note: A bypassed keyswitch sensor cannot arm or disarm the system. During an audible alarm,

Pagina 107 - Energy saver module (ESM)

Chapter 3: Programming Concord 4 Installation Manual 51 Phones - central station phone 1 to 3 settings Phone number Shortcut: 01000, 01010, and 0

Pagina 108 - Touchpad display contrast

Chapter 3: Programming 52 Concord 4 Installation Manual Backup Shortcut: 01005, 01015, and 01025 Default: On (1), Off (2 and 3) This setting deter

Pagina 109

Chapter 3: Programming Concord 4 Installation Manual 53 Low level reports Shortcut: 01032, 01042, 01052, 01062, and 01072 Default: Off This setti

Pagina 111

Chapter 3: Programming 54 Concord 4 Installation Manual Phones - downloader phone settings Phone number Shortcut: 01090 Default: None Use this sett

Pagina 112 - Troubleshooting

Chapter 3: Programming Concord 4 Installation Manual 55 that time. Communication failure Shortcut: 02003 Default: On This setting determines whet

Pagina 113

Chapter 3: Programming 56 Concord 4 Installation Manual Phone options - partition 1 to 6 settings Local phone control Shortcut: 0210 to 0260 Default

Pagina 114 - Arming and disarming issues

Chapter 3: Programming Concord 4 Installation Manual 57 Timers menu Timers -global settings Supervisory time Shortcut: 0300 Default: set random

Pagina 115 - Bypassing issues

Chapter 3: Programming 58 Concord 4 Installation Manual Timers - partition 1 to 6 settings Entry delay Shortcut: 0310 to 0360 Default: 30 seconds

Pagina 116 - Alphanumeric touchpad issues

Chapter 3: Programming Concord 4 Installation Manual 59 Light control menu The Light control menu lets you set up light activation for a specific

Pagina 117 - Siren issues

Chapter 3: Programming 60 Concord 4 Installation Manual Touchpad options menu Touchpad options - global settings Latchkey zones Shortcut: 0500 Defau

Pagina 118 - Wireless sensor zone issues

Chapter 3: Programming Concord 4 Installation Manual 61 Reporting menu Reporting - global settings 24-hour tamper Shortcut: 06000 Default: Off W

Pagina 119 - Phone issues

Chapter 3: Programming 62 Concord 4 Installation Manual Shortcut: 06007 Default: Off When turned off, no report is sent. Zone restorals Shortcut: 06

Pagina 120 - Energy saver module issues

Chapter 3: Programming Concord 4 Installation Manual 63 Flow battery report Shortcut: 06013 Default: Weekly This setting determines whether the

Pagina 121 - Automation module issues

Concord 4 Installation Manual 1 Chapter 1 Introduction Summary This chapter provides information to help you plan your Concord 4 panel and system i

Pagina 122

Chapter 3: Programming 64 Concord 4 Installation Manual Reporting - partition 1 to 6 settings Opening reports Shortcut: 06100 to 06600 Default: Of

Pagina 123 - System planning sheets

Chapter 3: Programming Concord 4 Installation Manual 65 Latchkey format Shortcut: 06105 to 06605 Default: Off This setting determines whether t

Pagina 124 - Wireless devices

Chapter 3: Programming 66 Concord 4 Installation Manual Siren options menu Siren options - global settings Immediate beeps Shortcut: 0700 Default:

Pagina 125 - Hardware devices

Chapter 3: Programming Concord 4 Installation Manual 67 Sensors menu Learn sensors Shortcut: 080 Default: None The panel comes with factory prog

Pagina 126

Chapter 3: Programming 68 Concord 4 Installation Manual Sensor text Shortcut: 081 Default: None Use the following guidelines to name zone and sens

Pagina 127 - Zone and sensor assignments

Chapter 3: Programming Concord 4 Installation Manual 69 Edit sensors Shortcut: 083 Default: None This menu lets you view and, if desired, change

Pagina 128

Chapter 3: Programming 70 Concord 4 Installation Manual Table 12 below describes how to trip different types of sensors to program (learn) them in th

Pagina 129

Chapter 3: Programming Concord 4 Installation Manual 71 Audio verification menu The Audio verification menu lets you set up the audio verification

Pagina 130

Chapter 3: Programming 72 Concord 4 Installation Manual Access code Shortcut: 09006 Default: **** or None This setting determines the four-digit

Pagina 131

Chapter 3: Programming Concord 4 Installation Manual 73 Accessory modules menu The Accessory modules menu gives you access to the following menus:

Pagina 132

Chapter 1: Introduction 2 Concord 4 Installation Manual Planning the installation This section describes system capabilities to help you get familiar

Pagina 133

Chapter 3: Programming 74 Concord 4 Installation Manual Device ID Default: None This menu lets you change the bus device ID number when replacing

Pagina 134

Chapter 3: Programming Concord 4 Installation Manual 75 Output programming Use these settings to program the output points of any installed SuperB

Pagina 135 - Reference tables

Chapter 3: Programming 76 Concord 4 Installation Manual Freeze temperatures Default: 42°F This setting determines the temperature point (40 to 90°

Pagina 136 - Sensor group characteristics

Chapter 3: Programming Concord 4 Installation Manual 77 Output text Shortcut: 10120 to 10123 Default: None Entering text for an output allows the

Pagina 137

Chapter 3: Programming 78 Concord 4 Installation Manual Onboard options menu The Onboard options menu includes input, output programming, and output

Pagina 138 - Appendix B: Reference tables

Chapter 3: Programming Concord 4 Installation Manual 79 Onboard options - output programming settings Output 1, 2 Shortcuts: 11100 (output 1ptn)

Pagina 139 - Cross-zoning

Chapter 3: Programming 80 Concord 4 Installation Manual Onboard options - output text settings Output text Shortcut: 1120 to 1121 Default: None Ent

Pagina 140 - Sensor text

Chapter 3: Programming Concord 4 Installation Manual 81 Macro keys menu The macro keys menu lets you set up single-button system commands with th

Pagina 141

Chapter 3: Programming 82 Concord 4 Installation Manual User programming mode The user programming mode allows you to view system version informatio

Pagina 142 - System event triggers

Chapter 3: Programming Concord 4 Installation Manual 83 Away Schedule 00 to 15 [Off] Energy saver Low setpoint 45 to 89 [50] High setpoint 48 to

Pagina 143 - Sensor group event triggers

Chapter 1: Introduction Concord 4 Installation Manual 3 Built-in RF receiver Allows use of up to 96 (Concord 4) or 32 (Concord Express v4) 319.5

Pagina 144 - Sensor number event triggers

Chapter 3: Programming 84 Concord 4 Installation Manual User codes menu The user codes menu lets you program/change regular user access codes, partit

Pagina 145

Chapter 3: Programming Concord 4 Installation Manual 85 Direct bypassing Shortcut: 030nnn1, where nnn is user number 00 to 229 Default: Off Th

Pagina 146

Chapter 3: Programming 86 Concord 4 Installation Manual Latchkey report Shortcut: 030nnn4, where nnn is user number 000 to 229 Default: On (for

Pagina 147

Chapter 3: Programming Concord 4 Installation Manual 87 System master Shortcut: 0320 Default: 1234 The system master code provides access to all

Pagina 148

Chapter 3: Programming 88 Concord 4 Installation Manual Set up schedules menu The set up schedules menu lets you set up timeframes for light control

Pagina 149 - Response numbers

Chapter 3: Programming Concord 4 Installation Manual 89 Set up schedules Shortcut: 05XXY, where XX is schedule 00 to 15 and Y is start (0)/s

Pagina 150

Chapter 3: Programming 90 Concord 4 Installation Manual Attach schedules to events menu This section describes how to link the system events to time

Pagina 151 - Specifications

Chapter 3: Programming Concord 4 Installation Manual 91 Lights Shortcut: 064xnn where nn is schedule number and x is light number minus 1 Defa

Pagina 152

Chapter 3: Programming 92 Concord 4 Installation Manual Arming Shortcut: 0660nn where nn is schedule number Default: Off This setting lets you arm

Pagina 153

Chapter 3: Programming Concord 4 Installation Manual 93 Light X to Sensor Y Shortcut: 08n where n is light number minus 1 Default: 0 This menu