Concord 4 Installation Manual P/N 466-2182 • REV J • NOV12
Chapter 1: Introduction 4 Concord 4 Installation Manual SnapCards The following SnapCards expand the system as described: 8Z input Snapcard: Provi
Chapter 3: Programming 94 Concord 4 Installation Manual A Downloader phone number should be programmed and the user-programmable option Downloading m
Concord 4 Installation Manual 95 Chapter 4 Testing and troubleshooting Summary This chapter provides information to help you test and troubleshoot
Chapter 4: Testing and troubleshooting 96 Concord 4 Installation Manual Testing the system Before testing, we recommend that you close the panel cabi
Chapter 4: Testing and troubleshooting Concord 4 Installation Manual 97 Command System response * (STATUS) Indicates current system status 7, 1 Tur
Chapter 4: Testing and troubleshooting 98 Concord 4 Installation Manual 4. Press the Status button when you think all zones/sensors are tested. T
Chapter 4: Testing and troubleshooting Concord 4 Installation Manual 99 3. If the display continues to show PHONE TEST for 90 seconds or more, ent
Chapter 4: Testing and troubleshooting 100 Concord 4 Installation Manual Codes System event 333 System armed to AWAY 555 Phone/sensor test 888 Syst
Chapter 4: Testing and troubleshooting Concord 4 Installation Manual 101 4. Verify that each output responds according to the programmed configura
Chapter 4: Testing and troubleshooting 102 Concord 4 Installation Manual To test the energy saver module: 1. Press *, * to display the system status
Chapter 4: Testing and troubleshooting Concord 4 Installation Manual 103 2. Press and release the 1 and 2 buttons together repeatedly, until the
Concord 4 Installation Manual 5 Chapter 2 Installation Summary This chapter provides information on locating and installing the panel and system c
Chapter 4: Testing and troubleshooting 104 Concord 4 Installation Manual 4. The central station operator waits for the alarm to be reported and ini
Chapter 4: Testing and troubleshooting Concord 4 Installation Manual 105
Chapter 4: Testing and troubleshooting 106 Concord 4 Installation Manual Troubleshooting This section provides information to help you diagnose and s
Chapter 4: Testing and troubleshooting Concord 4 Installation Manual 107 No incoming AC voltage at panel terminals 1 and 2. 1. Unplug the AC pow
Chapter 4: Testing and troubleshooting 108 Concord 4 Installation Manual • Check that the transformer is supplying AC to the panel. WARNING: Be car
Chapter 4: Testing and troubleshooting Concord 4 Installation Manual 109 • The installer code is being used to disarm the system. The system is de
Chapter 4: Testing and troubleshooting 110 Concord 4 Installation Manual The negative red lead or (RING) wires must connect to terminal 28 on the b
Chapter 4: Testing and troubleshooting Concord 4 Installation Manual 111 • Touchpad is not connected to panel bus terminals or is wired incorre
Chapter 4: Testing and troubleshooting 112 Concord 4 Installation Manual Hardwired zone issues System doesn’t go into alarm when zone is tripped. •
Chapter 4: Testing and troubleshooting Concord 4 Installation Manual 113 Touchpad indicates [sensor #] supervisory. • Use an RF Sniffer (60-401) t
Chapter 2: Installation 6 Concord 4 Installation Manual Installation overview Before starting the installation, plan your system layout and progra
Chapter 4: Testing and troubleshooting 114 Concord 4 Installation Manual • Check RJ31X jack wiring and TELCO block wiring. Replace RJ31X jack if nec
Chapter 4: Testing and troubleshooting Concord 4 Installation Manual 115 The module room temperature setting has not been adjusted or was adjusted
Concord 4 Installation Manual 117 Appendix A System planning sheets Summary This appendix provides various system planning sheets for the Concord 4
Appendix A: System planning sheets 118 Concord 4 Installation Manual Customer information Table 19: Customer information Customer name Address Ci
Appendix A: System planning sheets Concord 4 Installation Manual 119 Part number Description Quantity 60-457 Dual button panic sensor 60-578 Water
Appendix A: System planning sheets 120 Concord 4 Installation Manual Part number Description Quantity mA (max.) Subtotal 60-804 2x20 VFD alphanumeric
Appendix A: System planning sheets Concord 4 Installation Manual 121 Zone and sensor assignments Table 22: Zone and sensor assignments No. RF zone
Appendix A: System planning sheets 122 Concord 4 Installation Manual No. RF zone Module bus ID number Module input number Group Partition Zone/sensor
Appendix A: System planning sheets Concord 4 Installation Manual 123 No. RF zone Module bus ID number Module input number Group Partition Zone/sens
Chapter 2: Installation Concord 4 Installation Manual 7 Figure 1: Panel and component locations on a wall Total system power and wire length guid
Appendix A: System planning sheets 124 Concord 4 Installation Manual No. RF zone Module bus ID number Module input number Group Partition Zone/sensor
Appendix A: System planning sheets Concord 4 Installation Manual 125 Setting reference (default) Shortcut number Setting Bypass reports (Off) 060
Appendix A: System planning sheets 126 Concord 4 Installation Manual Setting reference (default) Shortcut number Setting Global fire (Off) 0703 Gr
Appendix A: System planning sheets Concord 4 Installation Manual 127 Setting reference (default) Shortcut number Setting Opening reports (Off) 06
Appendix A: System planning sheets 128 Concord 4 Installation Manual Setting reference (default) Shortcut number Setting SnapCard output 1 (01400
Concord 4 Installation Manual 129 Appendix B Reference tables Summary This appendix provides reference tables and specifications. Content Error! Bo
Appendix B: Reference tables 130 Concord 4 Installation Manual Sensor group characteristics Table 24 below shows what the sensors on your Concord 4 s
Appendix B: Reference tables Concord 4 Installation Manual 131 # Name Application Alarm Delay Restoral Supervisory CS Report Chime (Level) Activ
Appendix B: Reference tables 132 Concord 4 Installation Manual # Name Application Alarm Delay Restoral Supervisory CS Report Chime (Level) Active
Appendix B: Reference tables Concord 4 Installation Manual 133 Cross-zoning Cross-zoning (two-trip) refers to two different group 18 sensors that m
Chapter 2: Installation 8 Concord 4 Installation Manual Table 4 below describes the maximum wire length allowed between compatible devices and the p
Appendix B: Reference tables 134 Concord 4 Installation Manual Sensor text Table 25 below provides sensor text with the applicable item number. Tabl
Appendix B: Reference tables Concord 4 Installation Manual 135 Item # Sensor text Item # Sensor text Item # Sensor text Item # Sensor text 029 Cabi
Appendix B: Reference tables 136 Concord 4 Installation Manual System event triggers Table 26 below describes the system event triggers. Table 26: Sy
Appendix B: Reference tables Concord 4 Installation Manual 137 System event Description Trigger number Closing report sent When a closing report h
Appendix B: Reference tables 138 Concord 4 Installation Manual Sensor number event triggers Table 28 below describes the sensor number event trigger
Appendix B: Reference tables Concord 4 Installation Manual 139 Sensor number State Trigger number State Trigger number Sensor 29 In alarm 157 Open
Appendix B: Reference tables 140 Concord 4 Installation Manual Sensor number State Trigger number State Trigger number Sensor 62 In alarm 190 Open 31
Appendix B: Reference tables Concord 4 Installation Manual 141 Sensor number State Trigger number State Trigger number Sensor 95 In alarm 223 Open
Appendix B: Reference tables 142 Concord 4 Installation Manual Feature State Trigger number Recent closing report Occurred 249 Sensor test Entered 25
Appendix B: Reference tables Concord 4 Installation Manual 143 Response characteristics Table 30 below describes the response characteristics. Tabl
Chapter 2: Installation Concord 4 Installation Manual 9 Device Max. wire length to panel Standby mA draw Alarm mA draw SuperBus 2000 energy saver
Appendix B: Reference tables 144 Concord 4 Installation Manual Response number Siren tracking Trip delay Response time 11 Yes [1] No Sustained [3]
Appendix B: Reference tables Concord 4 Installation Manual 145 Specifications Power requirements Auxiliary power output Class 2, 16.5 VAC, 40 V
147 Concord 4 Installation Manual
Chapter 2: Installation 10 Concord 4 Installation Manual Wire type Total system wire 22-gauge, unshielded 22-gauge, shielded 4,000 ft. 3,000 ft. T
Chapter 2: Installation Concord 4 Installation Manual 11 5. Partially insert screws into the two top mounting hole locations, then hang the pane
Chapter 2: Installation 12 Concord 4 Installation Manual Antenna shrouds Install a plastic antenna shroud (included with panel) over each antenna
Chapter 2: Installation Concord 4 Installation Manual 13 Optional SnapCards Use the SnapCard header on the right side of the panel (Figure 4 below)
Copyright © 2012 UTC Fire & Security Americas Corporation, Inc. Interlogix is part of UTC Climate Controls & Security, a unit of Unite
Chapter 2: Installation 14 Concord 4 Installation Manual Panel terminals Figure 5 below shows an overview of panel terminals. The following sections
Chapter 2: Installation Concord 4 Installation Manual 15 Intrusion detection devices Figure 6 below shows the typical wiring for NC and NO door/win
Chapter 2: Installation 16 Concord 4 Installation Manual Note: When using two-wire smoke detectors on zone 8, the two-wire smoke setting (in program
Chapter 2: Installation Concord 4 Installation Manual 17 Figure 8: Polarity reversal module OUT 2+12V GNDZONE 82W-SMK Polarity reversalmodule (p
Chapter 2: Installation 18 Concord 4 Installation Manual Speakers and sirens The panel provides one siren driver output for intrusion (steady), fir
Chapter 2: Installation Concord 4 Installation Manual 19 Figure 10: Connecting hardwired interior speakers SPKR SPKR SPKR SPKRNot usedNot used7
Chapter 2: Installation 20 Concord 4 Installation Manual Figure 11: Connecting exterior sirens Panel terminalsRedBlackOUT1 GND Output 2 Onboard outp
Chapter 2: Installation Concord 4 Installation Manual 21 Interrogator 200 audio verification module A maximum of two audio veification modules (AVM
Chapter 2: Installation 22 Concord 4 Installation Manual SuperBus 2000 touchpads SuperBus 2000 touchpads may have wires or screw terminals. All use
Chapter 2: Installation Concord 4 Installation Manual 23 Figure 15: Installing SuperBus 2000 modules SuperBus 2000 2-amp power supply (600-1019)
Concord 4 Installation Manual i Content Important information iii Chapter 1 Introduction 1 Planning the installation 2 SuperBus 2000 bus d
Chapter 2: Installation 24 Concord 4 Installation Manual Figure 17: Wiring transceivers +12VABGND/COMPanel terminalsTransceiver terminalsGND +12V
Chapter 2: Installation Concord 4 Installation Manual 25 of the cabinet using an optional plastic housing (part no. 60-800). Refer to the documenta
Chapter 2: Installation 26 Concord 4 Installation Manual Figure 20: Wiring for status and alarm (or status only) messages Module terminalsHardwired
Chapter 2: Installation Concord 4 Installation Manual 27 SuperBus 2000 8Z input and 4-relay output modules Connect the modules to the panel as show
Chapter 2: Installation 28 Concord 4 Installation Manual SuperBus 2000 wireless cellular gateway Connect the SuperBus 2000 wireless cellular gateway
Chapter 2: Installation Concord 4 Installation Manual 29 • For full line seizure, install an RJ31X phone jack on the premises phone line so the p
Chapter 2: Installation 30 Concord 4 Installation Manual Figure 25: Wiring an RJ31X jack and DB-8 cord BRN25 26 27 28TelcoHouseDB-8 cordRJ31X jackDea
Chapter 2: Installation Concord 4 Installation Manual 31 Backup battery Use the 60-681 (12 VDC, 4.5 or 5 Ah) or 60-680 (12 VDC, 7Ah) backup battery
Chapter 2: Installation 32 Concord 4 Installation Manual down onto the prongs of the plug while you are securing the transformer to the outlet box. 6
Concord 4 Installation Manual 33 Chapter 3 Programming Summary This chapter provides instructions on how to program the Concord 4 and includes desc
ii Concord 4 Installation Manual Troubleshooting 106 Appendix A System planning sheets 117 Customer information 118 Wireless devices 118 Ha
Chapter 3: Programming 34 Concord 4 Installation Manual Overview For onsite system programming, you must have an alphanumeric touchpad. You must u
Chapter 3: Programming Concord 4 Installation Manual 35 Figure 27: Programming touchpad Programming touchpadProgramming touchpad
Chapter 3: Programming 36 Concord 4 Installation Manual Quick programming mode Use the quick programming mode to program basic system programming wit
Chapter 3: Programming Concord 4 Installation Manual 37 Tier 1 programming menus There are two basic tiers of programming menus as shown in Table
Chapter 3: Programming 38 Concord 4 Installation Manual System programming Use this setting to access the tier 2 programming menus. (See “Tier 2
Chapter 3: Programming Concord 4 Installation Manual 39 Partition 1 copy Default = None After programming all settings pertaining to partition 1
Chapter 3: Programming 40 Concord 4 Installation Manual Tier 2 programming menus Table 10 below shows the tier 2 system programming menus. Where app
Chapter 3: Programming Concord 4 Installation Manual 41 Pager 4 Phone number (01060) [None] High lvl rpts (01061) [On] Low lvl rpts (01062) [On
Chapter 3: Programming 42 Concord 4 Installation Manual Reporting Global 24-hour tamper (06000) [Off] Antenna tamper (06001) [Off] Buffer contro
Chapter 3: Programming Concord 4 Installation Manual 43 Accessory modules Bus device Unit – ID (10000 to 10015) [Off] Change ID Device ID
Concord 4 Installation Manual iii Important information Intended use Use this product only for the purpose it was designed for; refer to the data s
Chapter 3: Programming 44 Concord 4 Installation Manual The following sections guide you through the tier 2 system programming menu items as they
Chapter 3: Programming Concord 4 Installation Manual 45 Security menu Security - global settings Downloader code Shortcut: 0000 Default: 12345 Us
Chapter 3: Programming 46 Concord 4 Installation Manual Multipartition arm/disarm Shortcut: 0004 Default: Off. Partition to turn on This feature co
Chapter 3: Programming Concord 4 Installation Manual 47 Keyfob PTN Shortcut: 0006 Default: On This feature controls which partitions the selected
Chapter 3: Programming 48 Concord 4 Installation Manual 5. Press # and the display stops flashing. To disable keyfob PTN: 1. Enter this menu (display
Chapter 3: Programming Concord 4 Installation Manual 49 Security - partition 1 to 6 settings Account number Shortcut: 0010 to 0060 Default: 0000
Chapter 3: Programming 50 Concord 4 Installation Manual Note: A bypassed keyswitch sensor cannot arm or disarm the system. During an audible alarm,
Chapter 3: Programming Concord 4 Installation Manual 51 Phones - central station phone 1 to 3 settings Phone number Shortcut: 01000, 01010, and 0
Chapter 3: Programming 52 Concord 4 Installation Manual Backup Shortcut: 01005, 01015, and 01025 Default: On (1), Off (2 and 3) This setting deter
Chapter 3: Programming Concord 4 Installation Manual 53 Low level reports Shortcut: 01032, 01042, 01052, 01062, and 01072 Default: Off This setti
Chapter 3: Programming 54 Concord 4 Installation Manual Phones - downloader phone settings Phone number Shortcut: 01090 Default: None Use this sett
Chapter 3: Programming Concord 4 Installation Manual 55 that time. Communication failure Shortcut: 02003 Default: On This setting determines whet
Chapter 3: Programming 56 Concord 4 Installation Manual Phone options - partition 1 to 6 settings Local phone control Shortcut: 0210 to 0260 Default
Chapter 3: Programming Concord 4 Installation Manual 57 Timers menu Timers -global settings Supervisory time Shortcut: 0300 Default: set random
Chapter 3: Programming 58 Concord 4 Installation Manual Timers - partition 1 to 6 settings Entry delay Shortcut: 0310 to 0360 Default: 30 seconds
Chapter 3: Programming Concord 4 Installation Manual 59 Light control menu The Light control menu lets you set up light activation for a specific
Chapter 3: Programming 60 Concord 4 Installation Manual Touchpad options menu Touchpad options - global settings Latchkey zones Shortcut: 0500 Defau
Chapter 3: Programming Concord 4 Installation Manual 61 Reporting menu Reporting - global settings 24-hour tamper Shortcut: 06000 Default: Off W
Chapter 3: Programming 62 Concord 4 Installation Manual Shortcut: 06007 Default: Off When turned off, no report is sent. Zone restorals Shortcut: 06
Chapter 3: Programming Concord 4 Installation Manual 63 Flow battery report Shortcut: 06013 Default: Weekly This setting determines whether the
Concord 4 Installation Manual 1 Chapter 1 Introduction Summary This chapter provides information to help you plan your Concord 4 panel and system i
Chapter 3: Programming 64 Concord 4 Installation Manual Reporting - partition 1 to 6 settings Opening reports Shortcut: 06100 to 06600 Default: Of
Chapter 3: Programming Concord 4 Installation Manual 65 Latchkey format Shortcut: 06105 to 06605 Default: Off This setting determines whether t
Chapter 3: Programming 66 Concord 4 Installation Manual Siren options menu Siren options - global settings Immediate beeps Shortcut: 0700 Default:
Chapter 3: Programming Concord 4 Installation Manual 67 Sensors menu Learn sensors Shortcut: 080 Default: None The panel comes with factory prog
Chapter 3: Programming 68 Concord 4 Installation Manual Sensor text Shortcut: 081 Default: None Use the following guidelines to name zone and sens
Chapter 3: Programming Concord 4 Installation Manual 69 Edit sensors Shortcut: 083 Default: None This menu lets you view and, if desired, change
Chapter 3: Programming 70 Concord 4 Installation Manual Table 12 below describes how to trip different types of sensors to program (learn) them in th
Chapter 3: Programming Concord 4 Installation Manual 71 Audio verification menu The Audio verification menu lets you set up the audio verification
Chapter 3: Programming 72 Concord 4 Installation Manual Access code Shortcut: 09006 Default: **** or None This setting determines the four-digit
Chapter 3: Programming Concord 4 Installation Manual 73 Accessory modules menu The Accessory modules menu gives you access to the following menus:
Chapter 1: Introduction 2 Concord 4 Installation Manual Planning the installation This section describes system capabilities to help you get familiar
Chapter 3: Programming 74 Concord 4 Installation Manual Device ID Default: None This menu lets you change the bus device ID number when replacing
Chapter 3: Programming Concord 4 Installation Manual 75 Output programming Use these settings to program the output points of any installed SuperB
Chapter 3: Programming 76 Concord 4 Installation Manual Freeze temperatures Default: 42°F This setting determines the temperature point (40 to 90°
Chapter 3: Programming Concord 4 Installation Manual 77 Output text Shortcut: 10120 to 10123 Default: None Entering text for an output allows the
Chapter 3: Programming 78 Concord 4 Installation Manual Onboard options menu The Onboard options menu includes input, output programming, and output
Chapter 3: Programming Concord 4 Installation Manual 79 Onboard options - output programming settings Output 1, 2 Shortcuts: 11100 (output 1ptn)
Chapter 3: Programming 80 Concord 4 Installation Manual Onboard options - output text settings Output text Shortcut: 1120 to 1121 Default: None Ent
Chapter 3: Programming Concord 4 Installation Manual 81 Macro keys menu The macro keys menu lets you set up single-button system commands with th
Chapter 3: Programming 82 Concord 4 Installation Manual User programming mode The user programming mode allows you to view system version informatio
Chapter 3: Programming Concord 4 Installation Manual 83 Away Schedule 00 to 15 [Off] Energy saver Low setpoint 45 to 89 [50] High setpoint 48 to
Chapter 1: Introduction Concord 4 Installation Manual 3 Built-in RF receiver Allows use of up to 96 (Concord 4) or 32 (Concord Express v4) 319.5
Chapter 3: Programming 84 Concord 4 Installation Manual User codes menu The user codes menu lets you program/change regular user access codes, partit
Chapter 3: Programming Concord 4 Installation Manual 85 Direct bypassing Shortcut: 030nnn1, where nnn is user number 00 to 229 Default: Off Th
Chapter 3: Programming 86 Concord 4 Installation Manual Latchkey report Shortcut: 030nnn4, where nnn is user number 000 to 229 Default: On (for
Chapter 3: Programming Concord 4 Installation Manual 87 System master Shortcut: 0320 Default: 1234 The system master code provides access to all
Chapter 3: Programming 88 Concord 4 Installation Manual Set up schedules menu The set up schedules menu lets you set up timeframes for light control
Chapter 3: Programming Concord 4 Installation Manual 89 Set up schedules Shortcut: 05XXY, where XX is schedule 00 to 15 and Y is start (0)/s
Chapter 3: Programming 90 Concord 4 Installation Manual Attach schedules to events menu This section describes how to link the system events to time
Chapter 3: Programming Concord 4 Installation Manual 91 Lights Shortcut: 064xnn where nn is schedule number and x is light number minus 1 Defa
Chapter 3: Programming 92 Concord 4 Installation Manual Arming Shortcut: 0660nn where nn is schedule number Default: Off This setting lets you arm
Chapter 3: Programming Concord 4 Installation Manual 93 Light X to Sensor Y Shortcut: 08n where n is light number minus 1 Default: 0 This menu