Appendix C
108 Concord Express Installation Instructions
Central Station Reports
An exit error event now sends an Entry/Exit Alarm and Exit Error reports to
the central station.
In CID format the report is: (CID: 457,user# and 134,zone#)
IN SIA format the report is: (SIA: EE,user# and BA,zone#)
Entry Delay
During Entry Delay the system can now be disarmed by entering a valid
access code only. 1 + CODE is no longer required, but will still work.
The low limit and default setting on Entry Delay has been changed from 32 to
30 seconds. Existing versions of Toolbox will still show a low limit and default
setting of 32 seconds. When setting the Entry Delay in installer program
mode, entering any number between 30 and 39 will result in an Entry Delay of
30 seconds.
Exit Delay
The low limit on Exit Delay has been changed from 48 to 45 seconds, with the
default setting changing from 64 to 60 seconds. Existing versions of Toolbox
will still show a default setting of 64 seconds. When setting the Exit Delay in
installer program mode, entering any number between 45 and 55 will result in
an Exit Delay of 45 seconds and entering any number between 60 and 71 will
result in an Exit Delay of 60 seconds.
Dialer Abort Delay
The allowed range for Dialer Abort Delay (02006) has been changed from 15-
120 seconds to 15-45 seconds.
Abort delay is now used before every alarm, even alarms that occur during
another alarm report. In the previous release, an alarm that came in during
reporting of another event did not have a dial abort delay.
Disarming
Disarming the system after an alarm when the siren has timed out can now
be done by entering the access code. 1 + CODE is no longer required, but will
still work.
After disarming and canceling an alarm, the system now displays all the
alarms that have occurred since the last disarming.
Downloader
Eavesdrop delay for carrier detect on downloader call in is now 5 seconds
instead of 2 seconds. This change should eliminate problems connecting with
the downloader.