Appendix B: Reporting codes
NX-8E Control Panel Installation Manual 81
Go to program code and authorization
Segment 1
1 = Reserved
2 = Enable go to program code as an arm only code
3 = Enable go to program code as an arm only after
closing
4 = Enable go to program code as a master
arm/disarm code (can change user code)
5 = Enable go to program code as an arm/disarm
code
6 = Enable go to program code to bypass zones
7 = Enable go to program code opening and closing
reports
8 = Reserved
Segment 2
1 = Enable go to program code for partition 1
2 = Enable go to program code for partition 2
3 = Enable go to program code for partition 3
4 = Enable go to program code for partition 4
5 = Enable go to program code for partition 5
6 = Enable go to program code for partition 6
7 = Enable go to program code for partition 7
8 = Enable go to program code for partition 8
Auxiliary outputs 1 to 4 partition selection
Segment 1 = Output 1 partitions
Segment 2 = Output 2 partitions
Segment 3 = Output 3 partitions
Segment 4 = Output 4 partitions
Auxiliary outputs 1 to 4 special timing
Segments 1 to 4 (outputs 1 to 4)
1 = Aux output timed in minutes
3 = Aux output to stop timing upon user code
entry
4 = Aux output activates only betw een closing and
opening time
5 = Aux output activates only betw een opening and
closing time
6 = Invert aux output (0 V going to 12 V w hen
activated)
Auxiliary output 1 event/times
Segment 1 = Event number for output 1
Segment 2 = Timing for output 1
Auxiliary output 2 event/times
Segment 1 = Event number for output 2
Segment 2 = Timing for output 2
Auxiliary output 3 event/times
Comentarios a estos manuales