To program tone dialing, enter 15 in the segment wh
tone dialing begins.
ere
If the entire number is tone dialing, enter 15 in the first
segment.
Enter 11 for a *, and 12 for a #.
Caution: A call-waiting cancel on a non call-waiting line
prevents successful connection to the central station.
Location 1 - Phone 1 account code
Location 1 has six segments of numerical data. Use this
ne 1 is
in the
.
smit
n those listed, review
the override options described in “Location 18 - Custom
to build the appropriate
al format (in addition to
ocation 18). s 0. If this location
ntains a 0, the built-in co nd the NX-
2 fu cal-on
Table 4: Communicator form
ta
location to program the account code sent when pho
dialed. The default for each segment is 10. Program a 10
segment immediately after the last digit of the account code. If
the account code is six digits long, program all six segments
Location 2 - Phone 1 communicator format
Location 2 has one segment of numerical data. Use this
location to program the communicator format used to tran
to the receiver connected to phone 1. Refer to your central
station receiver documentation to determine which format is
compatible. Table 4 below describes the formats for this
locati
on. If you need a format other tha
communic
ator formaton page 5
format. Progra
m a 15 to create a speci
the entries in L The default i
co mmunicator is disabled a
4V nctions as a lo ly control.
ats
Da Format Description
0 Local nicator is disabled Commu
1 Universal 4+2 vent code 1800 Hz transmit
und parity
Two-digit e
2300 Hz handshake double ro
40 pps
a
2 3+1 fast (or 4+1)
y
One-digit event code 1900 Hz transmit
1400 Hz handshake double round parit
20 pps
3 Reserved Reserved
4 Pager
n
Two-digit event code DTMF
transmissio
5 3/1 or 4/1 slow 1800 Hz transmit 2300 Hz handshake
double round parity 20 pps hex
capability
6 3/1 or 4/1 slow 1800 Hz transmit 1400 Hz handshake
double round parity 20 pps hex
capability
Data Format Description
7 3/1 or 4/1 fast 1800 Hz transmit 2300 Hz handshake
double round parity 40 pps hex
capability
8 3/1 or 4/1 fast mit 1400 Hz handshake 1800 Hz trans
double round parity 40 pps hex
capability
9 3/1 or 4/1 fast with transmit 2300 Hz handshake
y 40 pps hex capabilityparity
1800 Hz
single round parit
10 3/1 or 4/1 f
parity
ast with
ake
pps hex capability
1800 Hz transmit 1400 Hz handsh
single round parity 40
11 4+2 express Two-digit event code DTMF
transmission
12 4+2 fast Two-digit event code 1900 Hz transmit
1400 Hz handshake double round parity
20 pps
13 Ademco contact ID DTMF
14 SIA Frequency shift keys
15 Custom format See “Location 18 - Custom
communicator formaton page 5
16 3/1 or 4/1 slow Same as 5, but sends the alarm event
code rather than the zone number
17 3/1 or 4/1 slow Same as 6, but sends the alarm event
code rather than the zone number
18 3/1 or 4/1 fast vent
e number
Same as 7, but sends the alarm e
code rather than the zon
19 3/1 or 4/1 fast Same as 8, but sends the alarm event
code rather than the zone number
20 3/1 or 4/1 fast with
parity
Same as 9, but sends the alarm even
code rather than the zone number
t
21 3/1 or 4/1 fast with Same as 10, but sends th
parity
e alarm event
code rather than the zone number
22 SIA SIA with area modifiers
a> Pulses per second.
Location 3 - Phone 1 dial attempts/backup control
al data.
com
tion
proc
Seg
to stop reporting.
Location 3 has two segments of numeric
Segment 1 - Phone 1 dial attempts
Program the n
umber of dial attempts (1 to 15) the
municator makes to phone 1 before ending the notifica
ess. The default is 8, which means that the communicator
makes eight attempts to the first number.
ment 2 - Phone 1 backup control
Program the b
ackup control for phone 1. The default is 0.
Program a 0 in segment 2 to cause the NX-4V2 to make
the designated number of attempts to phone 2 before
setting the fail to communicate condition