4.2.42 green-ethernet led on-event
Command:
green-ethernet led on-event error | link-change <0-65535>
error Set LEDs intensity to 100% if an error occurs.
link-change Specifies how long to turn LEDs intensity into 100%, when a link changes state.
<0-65535> Number of seconds to set LEDs intensity at 100% at link change.
Default:
N/A
Usage Guide:
To configure LED Power on-event to trigger LED light
Example:
To configure LED Power on-event as tabled below:
Switch# configure terminal
Switch (config)# green-ethernet led on-event error link-change 55
4.2.43 gvrp
Command:
gvrp
Default:
Disable
Usage Guide:
To enable GVRP.
Example:
To enable GVRP.
Switch# configure terminal
Switch (config)# gvrp
4.2.44 gvrp max-vlans