-21-
Chapter 2 CONSOLE CLI MANAGEMENT
2.1 Terminal Setup
To configure th e s ystem, co nnect a ser ial c able to a COM port on a PC or note book c omputer and t o RJ-45 t ype of seri al
(console) port of the Managed Switch.
Figure 2-1 Managed Switch Console Connectivity
A terminal pr ogram is re quired to make the software connection to th e Managed Switch. Windows' Hyper Terminal program
may be a good choice. The Hyper Terminal can be accessed from the Start menu.
1. Click START, then Programs, Accessories and then Hyper Terminal.
2. When the following screen appears, make sure that the COM port should be configured as:
Baud : 115200
Data bits : 8
Parity : None
Stop bits : 1
Flow control : None