Interlogix NS3702-24P-4S Command Line Guide Manual de usuario Pagina 240

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 405
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 239
-240-
Enabled
Usage Guide:
To enable System PoE Admin Mode.
Example:
To enable System PoE Admin Mode.
Switch# configure terminal
Switch (config)# poe admin-mode enable
4.2.137 poe management mode
Command:
poe management mode { class-consumption | class-reserved-power |
allocation-consumption | allocation-reserved-power | lldp-consumption |
lldp-reserved-power }
poe Power Over Ethernet
management Use management mode to configure PoE power management method.
mode mode
allocation-consumption Max. port power determined by allocated, and power is managed according to power
consumption.
allocation-reserved-power Max. port power determined by alocated, and is managed according to reserved power.
class-consumption Max. port power determined by class, and power is managed according to power consumption.
class-reserved-power Max. port power determined by class, and power managed according to reserved power.
lldp-consumption Max. port power determined by LLDP Media protocol, and power is managed according to
consumption.
lldp-reserved-power Max. port power determined by LLDP Media protocol, and power is managed according to
reserved power.
Default:
Allocation-consumption
Usage Guide:
To configure PoE Management Mode.
Example:
To configure PoE Management Mode as LLDP-consumption mode.
Vista de pagina 239
1 2 ... 235 236 237 238 239 240 241 242 243 244 245 ... 404 405

Comentarios a estos manuales

Sin comentarios