NS3702-24P-4S Command Line Guide P/N 1072833 • REV 00.01 • ISS 14JUL14
-9- 4.2.56.1 broadcast...
-100- Switch (config)# interface GigabitEthernet X/X Switch (config-if) # lldp tlv-select system-name 4.2.48.54 lldp transmit Command: lldp tran
-101- Switch (config)# interface GigabitEthernet X/X Switch (config-if) # loop-protect 4.2.48.56 loop-protect action Command: loop-protect actio
-102- Switch# configure terminal Switch (config)# interface GigabitEthernet X/X Switch (config-if) # loop-protect tx-mode 4.2.48.58 loop-protec
-103- Switch# configure terminal Switch (config)# interface GigabitEthernet X/X Switch (config-if) # mac address-table learning 4.2.48.60 medi
-104- Example: To configure MTU sizes (9000) for GigabitEthernet X/X Switch# configure terminal Switch (config)# interface GigabitEthernet X/X
-105- Inactive Usage Guide: To configure port role of specific MVR profile for specific interface Example: To configure port role (source) of MV
-106- network-clock network-clock synchronization SSM enable/disable. ssm SSM enable/disable. Default: Disable Usage Guide: To enab
-107- ping The ping command allows you to test connectivity to a network host from the appliance ip ip <ipv4_addr> IP address size
-108- 4.2.48.69 poe pdcheck IP Command: poe pdcheck IP <ipv4_addr> poe Power Over Ethernet. pdcheck Allows user to enab
-109- Switch# configure terminal Switch (config)# interface GigabitEthernet X/X Switch (config-if) # poe pdcheck action alarm 4.2.48.71 poe pd
-10- 4.2.76 ipmc profile ...
-110- Usage Guide: To configure PD Ping Alive Check interval of PoE for specific interface. Example: To configure PD Ping Alive Check interval (
-111- <1-5> retry-count <1-5> Default: 2 Usage Guide: To configure PD Ping Alive Check retry count of PoE for specific int
-112- poe priority { low | high | critical } poe Power Over Ethernet. priority Interface priority. critical Set priority to
-113- Switch (config-if) # poe time-range profile3 4.2.48.78 port-security Command: port-security port-security Enable/disable port secur
-114- Switch (config)# interface GigabitEthernet X/X Switch (config-if) # port-security maximum 100 4.2.48.80 port-security violation Command: p
-115- Default: None (Protected) Usage Guide: To configure protected mode of Port-security for specific interface Example: To configure protec
-116- None Usage Guide: To enable PVLAN isolation for specific interface Example: To enable PVLAN isolation for GigabitEthernet X/X Switch# con
-117- 0 Usage Guide: To configure DEI of QoS for specific interface Example: To configure DEI (1) of QoS for GigabitEthernet X/X Switch# config
-118- selected Classify to new DSCP if classify is enabled for specific DSCP value in global dscp-classify map zero Classify to new DSCP
-119- Command: qos dscp-translate qos Quality of Service dscp-translate DSCP ingress translation Default: Disabled Usage Guide
-11- 4.2.96 lldp timer...
-120- Example: To configure (QoS class, DP level) to (PCP, DEI) Mapping of QoS as below table for GigabitEthernet X/X Switch# configure terminal
-121- 4.2.48.92 qos pcp Command: qos pcp <Pcp : 0-7> qos Quality of Service pcp Priority Code Point configuration <
-122- Switch (config-if) # qos policer 9999 4.2.48.94 qos queue-policer queue Command: qos queue-policer queue <Queue : 0~7> <Rate : 10
-123- To configure Egress Queue Shapers Rate of QoS for specific interface Example: To configure Egress Queue (4) Shapers Rate (9999 Kbps) of QoS
-124- broadcast Police broadcast frames <Rate : 100-13200000> Policer rate (default kbps) fps Rate is fps Default: 500 Usa
-125- 4.2.48.99 qos storm unknown Command: qos storm unknown <Rate : 100-13200000> [fps] qos Quality of Service storm Stor
-126- Switch# configure terminal Switch (config)# interface GigabitEthernet X/X Switch (config-if) # qos tag-remark pcp 1 dei 1 4.2.48.101 qos
-127- Example: To enable DSCP Classification of QoS for GigabitEthernet X/X Switch# configure terminal Switch (config)# interface GigabitEthern
-128- interval Interval to sample data for each bucket. Default is 1800 seconds Default: N/A Usage Guide: To configure RMON History Confi
-129- 4.2.48.106 shutdown Command: shutdown shutdown Shutdown of the interface. Default: No shutdown Usage Guide: To shut down specifi
-12- 4.2.137 poe management mode...
-130- 4.2.48.108 spanning-tree auto-edge Command: spanning-tree auto-edge spanning-tree Spanning Tree protocol auto-edge Auto dete
-131- 4.2.48.110 spanning-tree edge Command: spanning-tree edge spanning-tree Spanning Tree protocol edge Ed ge port Default:
-132- Switch (config-if) # spanning-tree edge 4.2.48.112 spanning-tree mst <Instance : 0-7> cost Command: spanning-tree mst <Instance :
-133- Default: Auto Usage Guide: To configure Path Cost of CIST / MST Normal Port Configuration for specific interface Example: To enable
-134- Command: spanning-tree restricted-tcn spanning-tree Spanning Tree protocol restricted-tcn Restrict topology change notifications De
-135- Switch# configure terminal Switch (config)# interface GigabitEthernet X/X Switch (config-if) # speed 1000 4.2.48.117 switchport access vl
-136- Default: 1 Usage Guide: To add forbidden VLAN ID for specific interface Example: To add forbidden VLAN ID (5) for GigabitEthernet X/X
-137- 4.2.48.120 switchport hybrid acceptable-frame-type Command: switchport hybrid acceptable-frame-type all | tagged | untagged switchport Swi
-138- Default: All Usage Guide: To configure VLAN list of Hybrid VLAN for specific interface Example: To configure VLAN list (None) of Hyb
-139- 4.2.48.123 switchport hybrid ingress-filtering Command: switchport hybrid ingress-filtering switchport Switching mode characteristics hyb
-13- 4.2.172 snmp-server community ...
-140- Example: To enable PVID (5) in Hybrid VLAN mode for GigabitEthernet X/X Switch# configure terminal Switch (config)# interface GigabitEth
-141- switchport mode c-port | s-custom-port | s-port | unaware switchport Switching mode characteristics mode Set mode of the interface
-142- Usage Guide: To configure IP Subnet-based VLAN for specific interface Example: To configure IP Subnet-based VLAN as below table for Gigab
-143- Switch (config-if) # switchport vlan mac 00:55:44:33:22:11 vlan 5 4.2.48.129 switchport vlan mapping Command: switchport vlan mapping <
-144- None Usage Guide: To configure VLAN protocol group for specific interface Example: To configure VLAN protocol group as tabled below for
-145- 4.2.48.132 switchport voice vlan mode Command: switchport voice vlan mode auto | disable | force switchport Switching mode characterist
-146- Default: Disabled Usage Guide: To enable Voice VLAN security for specific interface Example: To enable Voice VLAN security for Giga
-147- 4.2.49.1 do Command: do < exec commands > do To run exec commands in config mode Default: N/A Usage Guide: To run exec
-148- Switch# configure terminal Switch (config)# interface vlan X Switch (config-if-vlan)# end Switch# 4.2.49.3 exit Command: exit exit
-149- Usage Guide: To configure IP address mode for specific VLAN Example: To configure IP address mode (192.168.1.10/24) for VLAN X Switch#
-14- 4.2.188.4 name ...
-150- ip Interface Internet Protocol config commands address Address configuraton dhcp Enable DHCP <ipv4_addr> D
-151- 4.2.49.8 ip igmp snooping Command: ip igmp snooping ip Interface Internet Protocol config commands igmp Internet Group Mana
-152- Auto Usage Guide: To configure IGMP snooping version for specific VLAN Example: To configure IGMP snooping V2 for VLAN X Switch# config
-153- Command: ip igmp snooping priority <CosPriority : 0-7> ip Interface Internet Protocol config commands igmp
-154- Switch# configure terminal Switch (config)# interface vlan X Switch (config-if-vlan)# ip igmp snooping querier address 192.168.1.15 4.2.49
-155- query-interval Query Interval in seconds <IpmcQi : 1-31744> 1 - 31744 seconds Default: 125 Usage Guide: To configure Qu
-156- 4.2.49.16 ip igmp snooping robustness-variable Command: ip igmp snooping robustness-variable <IpmcRv : 1-255> ip Interface In
-157- Example: To configure Unsolicited-Report-Interval (99 seconds) of IGMP snooping for VLAN X Switch# configure terminal Switch (config)# inte
-158- Default: Disabled Usage Guide: To enable MLD snooping for specific VLAN Example: To enable MLD snooping for VLAN X Switch# configure
-159- 4.2.49.21 ipv6 mld snooping last-member-query-interval Command: ipv6 mld snooping last-member-query-interval <IpmcLmqi : 0-31744>
-15- 4.15 more... 311 4.15.1
-160- Usage Guide: To configure CoS priority of MLD snooping for specific VLAN Example: To configure CoS priority (5) of MLD snooping for VLAN
-161- mld Multicast Listener Discovery snooping Snooping MLD query-interval Query Interval in seconds <IpmcQi : 1-31744&g
-162- Switch (config-if-vlan)# ipv6 mld snooping query-max-response-time 600 4.2.49.26 ipv6 mld snooping robustness-variable Command: ipv6 mld s
-163- 1 Usage Guide: To configure Unsolicited-Report-Interval of MLD snooping for specific VLAN Example: To configure Unsolicited-Report-Inter
-164- arp Address Resolution Protocol inspection ARP inspection Default: N/A Usage Guide: To enable ARP inspection Example:
-165- Switch# configure terminal Switch (config)# ip arp inspection entry interface GigabitEthernet 1/1 1 00:11:22:33:44:55 192.168.0.18 4.2.5
-166- ip Internet Protocol arp Address Resolution Protocol inspection ARP inspection translate arp inspection tra
-167- Default: N/A Usage Guide: To configure VLAN mode of ARP inspection. Example: To configure VLAN mode (VLAN 1, Log type: Permit) of AR
-168- ip dhcp pool <WORD> ip Internet Protocol dhcp Dynamic Host Configuration Protocol pool Configure DHCP
-169- 4.2.56.2 client-identifier fqdn Command: client-identifier fqdn <LINE> client-identifier Cl ient identifier fqdn FQDN
-16- 4.20.27 show ip dhcp relay...
-170- To configure Bind IP to MAC (00:11:22:33:44:55) of DHCP Server for pool “nsswitch” Switch# configure terminal Switch (config)# ip dhcp pool
-171- Example: To configure Default Gateway (192.168.0.1) of DHCP Server for pool “nsswitch” Switch# configure terminal Switch (config)# ip dhcp
-172- Usage Guide: To run exec commands Example: To run “show aaa”. Switch# configure terminal Switch (config)# ip dhcp pool nsswitch Switch (
-173- Command: End end Go back to EXEC mode Default: Auto Usage Guide: To back to EXEC mode Example: To back to EXEC mode Sw
-174- 4.2.56.11 hardware-address Command: hardware-address <MAC> hardware-address Client hardware address <MAC> Client
-175- Switch# configure terminal Switch (config)# ip dhcp pool nsswitch Switch (config-dhcp-pool)# host 192.168.1.10 255.255.255.0 4.2.56.13 leas
-176- To configure NetBIOS Name Server of DHCP Server. Example: To configure NetBIOS Name Server (192.168.1.10) of DHCP Server for pool “nsswitch
-177- <LINE> Netbios scope identifier, in 128 characters Default: None Usage Guide: To configure NetBIOS scope of DHCP Server. Exa
-178- 4.2.56.18 nis-domain-name Command: nis-domain-name <word128> nis-domain-name NIS domain name <word128> Domain name D
-179- Switch (config-dhcp-pool)# nis-server 1.1.1.1 4.2.56.20 no Command: no no Negate a command or set its defaults Default: N/A Usa
-17- 4.20.68 show port-security port ...
-180- Switch# configure terminal Switch (config)# ip dhcp pool nsswitch Switch (config-dhcp-pool)# ntp-server 1.1.1.1 4.2.56.22 vendor Command:
-181- Default: Disabled Usage Guide: To enable DNS proxy. Example: To enable DNS proxy. Switch# configure terminal Switch (config)# ip dn
-182- ip Internet Protocol http Hypertext Transfer Protocol secure-redirect Secure HTTP web redirection Default: Dis
-183- 4.2.61 ip igmp host-proxy Command: ip igmp host-proxy ip Internet Protocol igmp Internet Group Management Protocol
-184- Switch# configure terminal Switch (config)# ip igmp host-proxy leave-proxy 4.2.63 ip igmp snooping Command: ip igmp snooping ip
-185- Usage Guide: To enable IGMP Snooping for specific VLAN. Example: To enable IGMP Snooping for VLAN 1. Switch# configure terminal Switch (c
-186- unknown-flooding Flooding unregistered IPv4 multicast traffic Default: Enabled Usage Guide: To flood unregistered IPv4 multicast tr
-187- ip name-server dhcp ip Internet Protocol name-server Doma in Name System dhcp Dynamic Host Configuration Protocol
-188- 4.2.70 ip route Command: ip route <ipv4_addr> <ipv4_netmask> <ipv4_gateway> ip Internet Protocol route A
-189- Usage Guide: To enable IP routing Example: To enable IP routing Switch# configure terminal Switch (config)# ip routing 4.2.72 ip so
-19- Chapter 1 COMMAND LINE INTERFACE 1.1 Accessing the CLI When accessing the management interface for the switch over a direct connection to t
-190- 4.2.73 ip ssh Command: ip ssh ip Internet Protocol ssh Secure Shell Default: None Usage Guide: To enable SSH service Ex
-191- To enable IP Source Guard Switch# configure terminal Switch (config)# ip verify source 4.2.75 ip verify source translate Command: ip veri
-192- Usage Guide: To enable IPMC profile Example: To enable IPMC profile Switch# configure terminal Switch (config)# ipmc profile 4.2.77
-193- <EntryName : word16> Rang e entry name Default: None Usage Guide: To default IPMC Profile Rule for specific IPMC Profile
-194- Command: do < exec commands > do To run exec commands in config mode Default: N/A Usage Guide: To run exec commands Ex
-195- Switch (config-ipmc-profile)#end Switch# 4.2.77.5 exit Command: exit exit Exit from current mode Default: None Usa
-196- Switch# configure terminal Switch (config)# ipmc profile interlogix Switch (config-ipmc-profile)# no description 999 4.2.77.7 range Comm
-197- Disabled Usage Guide: To enable MLD Proxy Example: To enable MLD Proxy. Switch# configure terminal Switch (config)# ipv6 mld host-proxy
-198- mld Multicast Listener Discovery snooping Sno oping MLD Default: Disabled Usage Guide: To enable MLD Snooping. Exampl
-199- Command: ipv6 mld ssm-range <ipv6_mcast> <Ipv6PrefixLength : 8-128> ipv6 IPv6 configuration commands mld Multicas
-1- Copyright © 2014 United Technologies Corporation Interlogix is part of UTC Building & Industrial Systems,Inc. a unit of United Technologie
-20- The CLI provides the following modes: User Mode When the operator logs into the CLI, the User Mode is the initial mode. The User Mode
-200- 4.2.84 ipv6 route Command: Ipv6 route <X:X:X:X::X/<0-128>> {<X:X:X:X::X>, interface vlan <vlan_id> <FE80::X:X:X
-201- 4.2.85 lacp system-priority Command: lacp system-priority <1-65535> lacp LACP settings system-priority S ystem priority
-202- To enter line mode (vty 1) Switch# configure terminal Switch (config)# line vty 1 Switch (config-line)# 4.2.86.1 do Command: do < exec
-203- Enabled Usage Guide: To allow user editing command line. Example: To allow user editing command line. Switch# configure terminal Switch
-204- exec-banner Enable the display of the EXEC banner Default: Enabled Usage Guide: To enable the display of the EXEC banner
-205- 4.2.86.6 exec-timeout Command: exec-timeout <0-1440> exec-timeout Set the EXEC timeout <0-1440> T imeout in minutes
-206- Switch (config-line)# exit Switch (config)# 4.2.86.8 history size Command: history size <0-32> history Control the com
-207- To configure displayed lines on a screen. Example: To configure displayed lines on a screen. Switch# configure terminal Switch (config)# l
-208- Enabled Usage Guide: To enable MOTD banner. Example: To enable MOTD banner.. Switch# configure terminal Switch (config)# line vty 1 Swi
-209- level Assign default privilege level for line <0-15> Default privilege level for line Default: 15 Usage Guide:
-21- Chapter 2 CONSOLE CLI MANAGEMENT 2.1 Terminal Setup To configure th e s ystem, co nnect a ser ial c able to a COM port on a PC or note book
-210- 4.2.87 lldp holdtime Command: lldp holdtime <2-10> lldp LLDP configurations. holdtime Sets LLDP hold time (The neighbo
-211- To configure Datum type of LLDP Example: To configure Datum type (nad83-mllw) of LLDP Switch# configure terminal Switch (config)# lldp m
-212- floors Specify the altitude in floor. <Meters or floors> Altitude value. meters Specify the altitude in meters. Default:
-213- 4.2.92 lldp med location-tlv latitude Command: lldp med location-tlv latitude north <Degrees> | south <Degrees> lldp
-214- Default: North, 0 Usage Guide: To configure longitude direction of LLDP-MED Example: To configure longitude direction (east, 5) of
-215- Default: 0 Usage Guide: To configure media-VLAN-policy of LLDP-MED Example: To configure media-VLAN-policy as below table of LLDP-M
-216- Command: lldp timer <5-32768> lldp LLDP configurations. timer Sets LLDP TX interval (The time between each LLDP
-217- 4.2.98 logging host Command: logging host <hostname> | <ipv4_ucast> logging Syslog host host <hostname>
-218- Example: To configure level of log server Switch# configure terminal Switch (config)# logging level error 4.2.100 logging on Command:
-219- Usage Guide: To enable Loop Protection Example: To enable Loop Protection Switch# configure terminal Switch (config)# loop-protect 4
-22- Figure 2-3 Hyper Terminal COM Port Configuration You can cha nge these settin gs, if desired, af ter you log o n. This management method is
-220- Default: 5 Usage Guide: To configure Transmission Time of Loop Protection Example: To configure Transmission Time (8) of Loop Prote
-221- <port_type_list> | GigabitEthernet <port_type_list> mac MAC table entries/configuration address-table MAC table entr
-222- Usage Guide: To configure Mirroring Port Example: To set Mirroring Port (GigabitEthernet 1/2) Switch# configure terminal Switch (confi
-223- Usage Guide: To enable MVR Example: To enable MVR Switch# configure terminal Switch (config)# mvr 4.2.109 mvr name <mvr_name> ch
-224- name MV R multicast name <MvrName : word16> MVR multicast VLAN name frame MVR control frame in TX priority Interface CoS
-225- Switch (config)# mvr name 123 frame tagged 4.2.112 mvr name <mvr_name> igmp-address Command: mvr name <mvr_name> igmp-address
-226- Usage Guide: To configure the Last Member Query Interval of MVR profile Example: To configure the Last Member Query Interval (50 secon
-227- mvr Multicast VLAN Registration configuration vlan MVR multicast vlan <vlan_list> MVR multicast VLAN list Default: N
-228- 4.2.117 mvr vlan <vlan_list> frame priority Command: mvr vlan <vlan_list> frame priority <CosPriority : 0-7> mvr Multi
-229- Example: To enable the IGMP/MLD frame tagged of MVR VLAN (123) Switch# configure terminal Switch (config)# mvr vlan 123 tagged 4.2.119 m
-23- 2.2 Logon to the Console Once the terminal is con nected to the devi ce, po wer on the Managed Sw itch, and the terminal will di splay “run
-230- <vlan_list> MVR multicast VLAN list last-member-query-interval Last Member Query Interval in tenths of seconds <IpmcLmqi
-231- 4.2.122 mvr vlan <vlan_list> name Command: mvr vlan <vlan_list> name mvr Multicast VLAN Registration configuration vlan
-232- Usage Guide: To configure preferred negotiation of network-clock Example: To configure preferred negotiation (slave) of network-clock (
-233- network-clock net work-clock clk-source clk-source - commands related to a specific clock source. <clk-source : 1-2> Cl
-234- Switch# configure terminal Switch (config)# network-clock clk-source 1 priority 1 4.2.127 network-clock clk-source <clk-source> ssm-o
-235- option EEC options eec1 EEC1: DPLL bandwidth = 3,5 Hz, pull-in range = +/-12 ppm eec2 EEC2: DPLL bandwidth = 0,1 Hz, pull
-236- To configure Clock Selection Mode (Forced Free Run) of network-clock Switch# configure terminal Switch (config)# network-clock selector fre
-237- ssm-holdover Hold Over SSM overwrite dnu dnu eec1 eec1 eec2 eec2 inv in v prc prc ssua s
-238- Switch# configure terminal Switch (config)# network-clock wait-to-restore 6 4.2.133 no Command: no no Negate a command or set its defa
-239- Switch# configure terminal Switch (config)# ntp 4.2.135 ntp server Command: ntp server <1-5> ip-address { <ipv4_var> | <i
-24- Show the current IP Address 1. At the “#” prompt, enter “show ip interface brief”. 2. The screen displays the current IP address and Sub
-240- Enabled Usage Guide: To enable System PoE Admin Mode. Example: To enable System PoE Admin Mode. Switch# configure terminal Switch (
-241- Switch# configure terminal Switch (config)# poe management mode lldp-consumption 4.2.138 poe sequential enable Command: poe sequential
-242- Usage Guide: To configure Sequential Power up Interval. Example: To configure Sequential Power up Interval (30 seconds per port). Swi
-243- supply Use poe supply to specify the maximum power the power supply can deliver. <1-XXX> Maximum power the power supply can deli
-244- poe temperature-threshold <0-100> poe Power Over Ethernet temperature-threshold Set a lower high temperature threshold for
-245- 4.2.145 poe-time-range Command: poe-time-range {profile1 | profile2 | profile3 | profile4} poe-time-range Used to create PoE time-range
-246- Example: To run “show aaa”. Switch# configure terminal Switch (config)# poe-time-range profile1 Switch (config-poe-time-range)#do show a
-247- exit Exit from current mode Default: None Usage Guide: To exit current mode Example: To exit current mode. Switch# co
-248- Command: periodic { Mon | Tue | Wed | Thu | Fri | Sat | Sun } <start_h> <start_m> to <end_h> <end_m> [ reboot <re
-249- reboot-only { Mon | Tue | Wed | Thu | Fri | Sat | Sun } <reboot_h> <reboot_m> reboot-only To create a periodic mode time
-25- 4. Repeat step 1 to check if the IP address is changed. Store current switch configuration 5. At the “#” prompt, enter the following comm
-250- Example: To enable the Port Security Switch# configure terminal Switch (config)# port-security 4.2.147 port-security aging Command: p
-251- 3600 Usage Guide: To configure the Aging Period of Port Security Example: To configure the Aging Period (159) of Port Security Switch#
-252- Switch# configure terminal Switch (config)# privilege dhcp-pool level 12 host 4.2.150 qos map cos-dscp Command: qos map cos-dscp <co
-253- Default: 0 Usage Guide: To configure the DSCP Classification Example: To configure the DSCP Classification (QoS Class 3: DSCP CS1)
-254- cs6 Class Selector PHB CS6 precedence 6(DSCP 48) cs7 Class Selector PHB CS7 precedence 7(DSCP 56) ef Expedited Fo
-255- be Default PHB(DSCP 0) for best effort traffic cs1 Class Selector PHB CS1 precedence 1(DSCP 8) cs2 Class Selec
-256- af12 Assured Forwarding PHB AF12(DSCP 12) af13 Assured Forwarding PHB AF13(DSCP 14) af21 Assured Forwarding PHB AF21(
-257- va } } to { <dscp_num_tr> | { be | af11 | af12 | af13 | af21 | af22 | af23 | af31 | af32 | af33 | af41 | af42 | af43 | cs1 | cs2 | cs3
-258- 4.2.155 qos qce Command: qos qce <qce_id> [ { next <qce_id_next> } | last ] [ interface ( <port_type> [ <port_list>
-259- Switch# configure terminal Switch (config)# qos qce 1 interface GigabitEthernet 1/1-2 tag type tagged vid 5 pcp 3 dei 1 dmac unicast fram
-26- Chapter 3 TELNET CLI MANAGEMENT 3.1 Telnet Login The Managed Switch also supports telnet for remote man agement. The switch asks for user nam
-260- [ pcp-dei { <action_pcp> <action_dei> | default } ] [ dscp { <action_dscp_dscp> | { be | af11 | af12 | af13 | af21 | af22 |
-261- Usage Guide: To refresh the QCE Example: To refresh the QCE. Switch# configure terminal Switch (config)# qos qce refresh 4.2.158 qo
-262- Example: To configure the Weighted Random Early Detection (below table) Switch# configure terminal Switch (config)# qos wred queue 1 mi
-263- radius-server attribute 4 <Ipv4 : ipv4_ucast> radius-server Configure RADIUS 4 NAS-IP-Address Default: None Usage Gui
-264- 4.2.162 radius-server deadtime Command: radius-server deadtime <Minutes : 1-1440> radius-server Configure RADIUS d
-265- Default: None Usage Guide: To configure the Host of Radius-Server Example: To configure the Host (below table) of Radius-Server Sw
-266- 4.2.165 radius-server retransmit Command: radius-server retransmit <Retries : 1-1000> radius-server Configure RAD
-267- Switch# configure terminal Switch (config)# radius-server timeout 10 4.2.167 rmon alarm Command: rmon alarm <id> {<oid_str>
-268- <rising_event_id: 0-65535> Event to fire on rising threshold crossing falling-threshold Configure the falling thr
-269- Usage Guide: To configure the Event of RMON Example: To configure the Event (below table) of RMON Switch# configure terminal Switch
-27- Chapter 4 Commands for CLI Configuration 4.1 clear 4.1.1 clear access management statistics Command: clear access management statistics Def
-270- Default: Enabled Usage Guide: To enable the SNMP Service Example: To enable the SNMP Service Switch# configure terminal Switch (co
-271- Example: To configure the Access (below table) of SNMP Switch# configure terminal Switch (confi g)# snmp-server access default_rw_group
-272- Switch (config)# snmp-server community v3 public 192.168.0.15 255.255.255.0 4.2.173 snmp-server contact Command: snmp-server contact <
-273- Usage Guide: To configure the Engine IDof SNMP Example: To configure the Engine ID (1234567890) of SNMP Switch# configure terminal Swi
-274- do < exec commands > do To run exec commands. Default: N/A Usage Guide: To run exec commands. Example: To run “show aa
-275- 4.2.175.3 exit Command: exit exit Exit from current mode Default: None Usage Guide: To exit current mode Example:
-276- Usage Guide: To configure Trap Host of SNMP Example: To configure Trap Host (below table) of SNMP Switch# configure terminal Switch (
-277- informs retries <retries> timeout <timeout> informs Send Inform messages to this host retries retires inform messa
-278- Switch (config)# snmp-server host interlogix Switch (config-snmps-host)# shutdown 4.2.175.8 traps Command: traps [ aaa authentication ]
-279- <v_word10_to_32> ] [ <securtyname> ] } version Set SNMP trap version v1 SNMP trap version 1 <V1Comm : word1
-28- 4.1.3 clear dot1x statistics interface Command: clear dot1x statistics interface GigabitEthernet Default: N/A Usage Guide: To clear the
-280- To enter aggregation mode of STP Example: To enter aggregation mode of STP Switch# configure terminal Switch (config)# spanning-tree agg
-281- end Go back to EXEC mode Default: Auto Usage Guide: To back to EXEC mode Example: To back to EXEC mode Switch# configur
-282- 4.2.176.4 no Command: no no Negate a command or set its defaults Default: N/A Usage Guide: To default the function Example: T
-283- Switch# configure terminal Switch (config)# snmp-server host interlogix Switch (config-snmps-host)# spanning-tree auto-edge 4.2.176.6 spa
-284- Example: To enable the Admin Edge of CIST Aggregated Port Switch# configure terminal Switch (config)# snmp-server host interlogix Switch
-285- cost STP Cost of this port <Cost : 1-200000000> Cost range auto Use auto cost Default: Auto Usage Guide:
-286- Switch (config-snmps-host)# spanning-tree mst 2 port-priority 96 4.2.176.11 spanning-tree restricted-role Command: spanning-tree restr
-287- To enable the Restricted TCN of CIST Switch# configure terminal (config)# spanning-tree aggregation (config-stp-aggr)# spanning-tree restr
-288- tacacs-server Configure TACACS+ deadtime Time to stop using a TACACS+ server that doesn't respond <Minutes : 1-144
-289- Switch# configure terminal Switch (config)# tacacs-server host interlogix.com port 55 timeout 6 key 7788 4.2.180 transport email authent
-29- Usage Guide: To clear the DHCP detailed statistics for all. Example: To clear the Switch’s DHCP detailed statistics for all. Switch# clear
-290- <mail_addr> mail address subject subject/title of the email <title> email title Default: N/A Usage Guide: To c
-291- Switch# configure terminal Switch (config)# transport email smtp-server mail.interlogix.com.tw port 123 4.2.183 transport email to Co
-292- Usage Guide: To enable the UPnP service Example: To enable the UPnP service Switch# configure terminal Switch (config)# upnp 4.2.185
-293- Default: 4 Usage Guide: To configure the TTL of UPnP Example: To configure the TTL (8) of UPnP Switch# configure terminal Switch
-294- Switch# configure terminal Switch (config)# username 1234 privilege 15 password unencrypted 1234 Press ENTER to get started Username: 1234
-295- Usage Guide: To run exec commands. Example: To run “show aaa”. Switch# configure terminal Switch (config)# vlan 5 Switch (config-vlan
-296- Command: exit exit Exit from current mode Default: None Usage Guide: To exit current mode Example: To exit current mode
-297- 4.2.188.5 no Command: no no Negate a command or set its defaults Default: N/A Usage Guide: To default the function Example: To
-298- Switch# configure terminal Switch (config)# vlan ethertype s-custom-port 0x88a9 4.2.190 vlan protocol Command: vlan protocol { { eth2
-299- Switch# configure terminal Switch (config)# vlan protocol llc 0x55 0x66 group 3 4.2.191 voice vlan Command: voice vlan voice Voice
-2- Contents Chapter 1 COMMAND LINE INTERFACE... 19 1.1 Accessing the CLI...
-30- 4.1.8 clear ip dhcp detailed statistics server Command: clear ip dhcp detailed statistics server Default: N/A Usage Guide: To clear the
-300- Example: To configure the Aging Time of Voice VLAN Switch# configure terminal Switch (config)# voice vlan aging-time 8888 4.2.193 voic
-301- description Set description for the OUI <Description : line32> Description line Default: None Usage Guide: To
-302- 4.2.196 web privilege group Command: web privilege group <group_name> level { [ cro <cro: 0-15> ] [ crw <crw: 0-15> ] [ sr
-303- Command: copy { startup-config | running-config | <source_path> } { startup-config | running-config | <destination_path> } [ syn
-304- Usage Guide: To configure Description of Debug Prompt Example: To configure Description (1233) of Debug Prompt Switch # debug prompt 123
-305- Switch # dir Directory of flash: r- 1970-01-01 00:00:00 648 default-config r w 1970-01-01 07:26:26 183 3 startup-config
-306- Command: disable disable Turn off privileged commands Default: None Usage Guide: To e x it enable mode Example: To e x it e
-307- 4.9 dot1x 4.9.1 dot1x initialize Command: dot1x initialize [ interface ( <port_type> [ <plist> ] ) ] dot1x IEEE Standa
-308- Example: To enter enable mode Switch > enable Switch # 4.11 exit 4.11.1 exit Command: exit exit Exit from EXEC mode Defaul
-309- swap Swap between Active and Alternate firmware image Default: None Usage Guide: To swap Active and Alternate firmware image E
-31- Default: N/A Usage Guide: To clear the DHCP relay statistics. Example: To clear the Switch’s DHCP relay statistics. Switch# clear ip dhcp
-310- 4.13 ip 4.13.1 ip dhcp retry interface vlan Command: ip dhcp retry interface vlan <vlan_id> ip IPv4 commands dhcp Dh
-311- Example: To exit EXEC mode Switch # logout Press ENTER to get started 4.15 more 4.15.1 more Command: more <path> more Di
-312- 4.16 no 4.16.1 no Command: no no Negate a command or set its defaults Default: N/A Usage Guide: To default the function Ex
-313- <Size : 2-1452> 2-1452; Default is 56 (excluding MAC, IP and ICMP headers) Default: N/A Usage Guide: To run the IPv4 Ping
-314- Usage Guide: To run the IPv6 Ping function Example: To run the IPv6 Ping (2001::7788) function Switch# ping ipv6 2001::7788 PING6 se
-315- 4.18.2 reload defaults Command: reload defaults [ keep-ip ] reload Re load system defaults Reload defaults without rebooting. kee
-316- To send message for command line user. Example: To send message ( hi, I will upgrade the firmware, OK? ) for command line user (All).
-317- console : local telnet : local ssh : local http : local 4.20.2 show access management Command: show access management [ stati
-318- Command: show access-list [ interface [ ( <port_type> [ <v_port_type_list> ] ) ] ] [ rate-limiter [ <rate_limiter_list> ]
-319- --------------------- GigabitEthernet 1/1 access-list action is permit GigabitEthernet 1/1 access-list policy ID is 0 GigabitEthernet 1/1 acc
-32- Switch# clear ip dhcp server binding automatic 4.1.13 clear ip dhcp server binding expired Command: clear ip dhcp server binding expired
-320- Switch access-list rate limiter ID 4 is 1 pps Switch access-list rate limiter ID 5 is 1 pps Switch access-list rate limiter ID 6 is 1 pps Swi
-321- link-oam The ACEs that are configured by Link OAM module loop-protect The ACEs that are configured by Loop Protect module
-322- Command: show aggregation [ mode ] show Show running system information aggregation Aggregation port configuration m
-323- SMAC : Enabled DMAC : Disabled IP : Enabled Port : Enabled 4.20.8 show clock Command: show clock show Show running
-324- Default: N/A Usage Guide: To display the detailed system time. Example: To display the detailed system time. Switch # show clock
-325- statistics Shows statistics for either eapol or radius all Show all dot1x statistics eapol Show EAPOL statistics
-326- 4.20.11 show dot1x status Command: show dot1x status [ interface ( <port_type> [ <v_port_type_list> ] ) ] [ brief ] show
-327- 4.20.12 show green-ethernet Command: show green-ethernet [ interface ( <port_type> [ <port_list> ] ) ] show Show r
-328- To display the energy-detect of Green Ethernet for all. Switch # show green-ethernet energy-detect interface * 4.20.14 show green-ethern
-329- To display the command history. Example: To display the command history. Switch # show history sho w green-ethernet interface Gigabit
-33- Command: clear ip igmp snooping statistics Default: N/A Usage Guide: To clear the IGMP snooping statistics. Example: To clear the Switch
-330- SFP Vendor revision: 4.20.17 show interface <port_type> <port_type_list> statistics Command: show interface <port_type>
-331- show interface <port_type> <port_type_list> status show Show running system information interface Interface sta
-332- Switch # show interface GigabitEthernet 1/1 switchport Name: GigabitEthernet 1/1 Administrative mode: access Access Mode VLAN: 1 Trunk Nativ
-333- Pair C L ength Pair D Length ------ ------ ------ ----- -- OK 3 OK 3 4.20.21 show interface <port_type>
-334- interface Interface status and configuration vlan VLAN status Default: N/A Usage Guide: To display the MAC address
-335- 192.168.0.78 via VLAN1:00-30-4f-97-72-2d 4.20.24 show ip dhcp detailed statistics Command: show ip dhcp detailed statistics { server | cli
-336- Rx Decline: 0 Tx Decline: 0 Rx ACK: 0 Tx ACK:
-337- Switch # show ip dhcp excluded-address Low Address High Address ------------ --- -------------- - 01 1 92.168.0.100 1
-338- Netbios name server is - Netbios node type is - Netbios scope identifier is - NIS domain name is - NIS server is - Ven
-339- Command: show ip dhcp server show Show running system information ip Internet Protocol dhcp Dynamic Host Configurati
-34- Usage Guide: To clear the IPv4 ICMP traffic for designated message type. Example: To clear the Switch’s IPv4 ICMP traffic for designated me
-340- manual Manual binding for a specific host <ip> IP address in dotted-decimal notation Default: N/A Usage Guid
-341- Command: show ip dhcp server statistics show Show running system information ip Internet Protocol dhcp Dynamic Hos
-342- Message Sent Counters ========================= OFFER 0 ACK 0 NAK 0 ==============
-343- snooping DHCP snooping table show ip dhcp snooping table Default: N/A Usage Guide: To display the DHCP Snooping ta
-344- 4.20.35 show ip igmp snooping Command: show ip igmp snooping [ vlan <vlan_list> ] [ group-database [ interface ( <port_type>
-345- igmp Internet Group Management Protocol snooping Snooping IGMP mrouter Multicast router port status in IGMP detai
-346- Switch # show ip interface brief Vlan Address Method S tatus ---- -------------------- -------- ------ 1 192.168.0.100/24
-347- Usage Guide: To display the IP Routing table. Example: To display the IP Routing table. Switch # show ip route 11.11.11.0/24 via 192
-348- Type Port VLAN IP Address IP Mask ---- ---- ---- ---------- ------- St
-349- Usage Guide: To display the IP statistics. Example: To display the IP statistics. Switch # show ip statistics IPv4 statistics:
-35- 4.1.20 clear ip statistics system icmp interface vlan Command: clear ip statistics system icmp interface vlan <vlan_list> VLAN i
-350- IPv4 ICMP statistics: Rcvd: 2618 Messages, 0 Error Sent: 2618 Messages, 0 Error ICMP message statistics: IPv4 ICMP Message: Ec
-351- 4.20.44 show ipmc profile Command: show ipmc profile [ <profile_name> ] [ detail ] show Show running system information
-352- Default: N/A Usage Guide: To display the IP Multicast Range. Example: To display the IP Multicast Range. Switch # show ipmc ran
-353- Internet address is fe80::201:c1ff:fe00:2000 Static address is 2001::7766/64 IP stack index (IFID) is 2 Routing is enabled on
-354- Usage Guide: To display the MLD Snooping information. Example: To display the MLD Snooping information (Detail). Switch # show ipv6
-355- 4.20.49 show ipv6 neighbor Command: show ipv6 neighbor [ interface vlan <vlan_list> ] show Show running system information
-356- To display the IPv6 Routing table. Example: To display the IPv6 Routing table. Switch # show ipv6 route ::1/128 via ::1 <UP HOST>
-357- Rcvd: 24 total in 2064 bytes 6 local destination, 0 forwarding 0 header error, 0 address error, 0 unknown protocol
-358- Sent: 10 Packets IPv6 ICMP Message: Router Solicitation (NDP) Rcvd: 3 Packets Sent: 6 Packets IPv6 ICMP Message: Neighbor So
-359- show line [ alive ] show Show running system information line TTY line information alive Display information about aliv
-36- <vlan_list> VLAN identifier(s): VID Default: N/A Usage Guide: To clear the ipv6 mld snooping statistics for specific VLAN. Examp
-360- media-vlan-policy Display media vlan policies <0~31> List of policies Default: N/A Usage Guide: To display the
-361- 4.20.56 show lldp neighbors Command: show lldp neighbors [ interface ( <port_type> [ <port_type_list> ] ) ] show Sho
-362- To display the LLDP statistics information for GigabitEthernet 1/1. Switch # show lldp statistics interface GigabitEthernet 1/1
-363- Loop Detected: Port 5 shut down 4.20.59 show loop-protect Command: show loop-protect [ interface ( <port_type> [ <port_list>
-364- 4.20.60 show mac address-table Command: show mac address-table [ conf | static | aging-time | { { learning | count } [ interface ( <por
-365- show mvr [ vlan <vlan_list> | name <mvr_name> ] [ group-database [ interface ( <port_type> [ <port_type_list> ] ) ] [
-366- 4.20.62 show network-clock Command: show network-clock show Show running system information network-clock Show selector stat
-367- ntp Configure NTP status status Default: N/A Usage Guide: To display the NTP Server information. Example: To display
-368- Switch # show platform phy interface GigabitEthernet 1/1 Port API Inst W AN/LAN/1G Mode Dupl ex S peed Link ----
-369- interface Search by port Default: N/A Usage Guide: To display the PHY ID. Example: To display the PHY ID for GigabitEtherne
-37- Example: To clear the Switch’s IPv6 ICMP traffic for designated message type 0. Switch# clear ipv6 statistics icmp icmp-msg 0 4.1.25 clear
-370- 1 No No 4.20.68 show port-security port Command: show port-security port [ interface ( &
-371- N/A Usage Guide: To display the status of Port Security. Example: To display the status of Port Security. Switch # show port-securit
-372- 4.20.71 show pvlan Command: show pvlan [ <pvlan_list> ] show Show running system information pvlan PVLAN configuration
-373- Switch # show pvlan isolation Port Isolation -------------------------------- --------- GigabitEther
-374- qos cos 0 qos pcp 0 qos dpl 0 qos dei 0 qos trust tag disabled qos map tag-cos pcp 0 dei 0 cos 1 dpl 0 qos map tag-cos pcp 0 de
-375- qos tag-remark classified qos map cos-tag cos 0 dpl 0 pcp 1 dei 0 qos map cos-tag cos 0 dpl 1 pcp 1 dei 1 qos map cos-tag cos 1 dpl 0
-376- Example: To display the RADIUS Server configuration. Switch # show radius-server Global RADIUS Server Timeout : 5 seconds Global RA
-377- Startup : risingOrFallingAlarm RisingThrld : 2 Fallin gThrld : 1 Risin gEventIndex : 2
-378- rmon RMON statistics history Display the RMON history table Default: N/A Usage Guide: To display the RMON History conf
-379- Switch # show rmon statistics 1 Statistics ID : 1 --------------------- Data Source : .1.3.6.1.2.1.2.2.1.1.5 etherS tatsDropEve
-38- 4.1.27 clear ipv6 statistics system icmp interface vlan Command: clear ipv6 statistics system icmp interface vlan <vlan_list> VLAN
-380- 'ip-igmp-snooping' 'ip-igmp-snooping-port' 'ip-igmp-snooping-vlan' 'ipmc-profile' 'ipmc-profile-
-381- ! ! mvr mvr vlan 1 name 1 4.20.80 show snmp Command: show snmp show Show running system information snmp Display SNMP co
-382- SNMPv3 Users Table: User Name : default_user Engine ID : 800007e5017f000001 Security Level : NoAuth,
-383- Security Level : NoAuth, NoPriv Read View Name : default_view Write View Name : default_view SNMPv3 Views Table: View Name : de
-384- Group Name : default_ro_group Security Model : any Security Level : NoAuth, NoPriv Read View Name : default_view Write View
-385- 4.20.83 show snmp host Command: show snmp host [ <conf_name> ] [ system ] [ switch ] [ interface ] [ aaa ] show Show running
-386- Usage Guide: To display the SNMP MIB contexts. Example: To display the SNMP MIB contexts. Switch # show snmp mib context BRIDGE-MIB :
-387- - snmpDot3MauMgt (.1.3.6.1.2.1.26) MGMD-MIB : - mgmdMIBObjects (.1.3.6.1.2.1.185.1) P-BRIDGE-MIB : - pBridgeMIB (.1.3.6.1.2.1.1
-388- 4.20.85 show snmp mib ifmib ifIndex Command: show snmp mib ifmib ifIndex show Show running system information snmp Display S
-389- 19 S witch 1 - Port 19 GigabitEther net 1/19 20 S witch 1 - Port 20 GigabitEther
-39- N/A Usage Guide: To clear the lldp statistics. Example: To clear the Switch’s lldp statistics. Switch# clear lldp statistics 4.1.30 clea
-390- Group Name : default_ro_group Security Model : v1 Security Name : private Group Name : default_rw_group Security Model : v2c
-391- Switch # show snmp user User Name : default_user Engine ID : 800007e5017f000001 Security Level : NoAut
-392- { mst [ configuration | { <instance> [ interface ( <port_type> [ <port_type_list> ] ) ] } ] } ] show Show running s
-393- show switchport forbidden [ { vlan <vid> } | { name <name> } ] show Show running system information switchport
-394- Global TACACS+ Server Deadtime : 0 minutes Global TACACS+ Server Key : No hosts configured! 4.20.92 show terminal Comman
-395- 4.20.93 show upnp Command: show upnp show Show running system information upnp Display UPnP configurations Default:
-396- Switch # show users Line is con 0. * You are at this line now. Con nection is from Console. User name is admin. Privile ge
-397- System Time : 1970-01-01T22:56:08+00:00 System Uptime : 22:56:08 Active Image ------------ Image : managed Version
-398- Switch # show vlan VLAN Name Interfaces ---- ------------- ------------------- ---------- 1 default
-399- Default: N/A Usage Guide: To display the MAC-based VLAN information. Example: To display the MAC-based VLAN information. Switch #
-3- 4.1.20 clear ip statistics system icmp interface vlan ...
-40- 4.1.32 clear logging info error Command: clear logging info error Default: N/A Usage Guide: To clear the logging info error. Example:
-400- N/A Usage Guide: To display the Protocol-based VLAN information. Example: To display the Protocol-based VLAN information. Switch #
-401- Switch # show voice vlan interface GigabitEthernet 1/1 GigabitEthernet 1/1 : --------------------- GigabitEthernet 1/1 switchport voice v
-402- Debug 15 15 15 15 DHCP 5 10 5 10 Dhcp_Client 5 10
-403- 4.21 terminal 4.21.1 terminal editing Command: terminal editing terminal Set terminal line parameters editing Enable comman
-404- Switch # terminal exec-timeout 500 4.21.3 terminal history size Command: terminal history size <history_size> terminal Se
-405- Example: To configure length of command display with 5 lines for current terminal session. Switch # terminal length 5 Switch # show run Bui
-41- Default: N/A Usage Guide: To clear the logging warning error. Example: To clear the Switch’s logging warning error. Switch# clear loggin
-42- Switch# clear mac address-table 4.1.37 clear mvr name Command: clear mvr name <MvrName : word16> <MvrName : word16> MVR mul
-43- Default: N/A Usage Guide: To clear the mvr vlan statistics for specific VLAN. Example: To clear the Switch’s mvr vlan statistics for spec
-44- To clear the Switch’s spanning-tree detected-protocols for all. Switch# clear spanning-tree detected-protocols interface * 4.1.42 clear spa
-45- Switch# clear spanning-tree detected-protocols interface GigabitEthernet 1/1 4.1.44 clear spanning-tree statistics interface * Command: cl
-46- Command: clear statistics * Default: N/A Usage Guide: To clear the statistics for all. Example: To clear the Switch’s statistics for all
-47- console : local Usage Guide: To authenticate the local account via console only. Example: To authenticate the local account via console. S
-48- Switch# configure terminal Switch (config)# aaa authentication login console local radius tacacs 4.2.4 aaa authentication login http local Co
-49- Command: aaa authentication login http tacacs Default: http : local Usage Guide: To authenticate the tacacs account via http only. Exampl
-4- 4.2.13 access management ...
-50- To authenticate the radius account via ssh only. Example: To authenticate the local and radius account via ssh. Switch# configure terminal S
-51- Switch (config)# aaa authentication login telnet local 4.2.11 aaa authentication login telnet radius Command: aaa authentication login teln
-52- Command: access management <AccessId : 1-16> <AccessVid : 1-4095> <AddrRangeStart : ipv4_addr | ipv6_addr> all | snmp | tel
-53- frametype Frame type ingress Ingress logging Logging frame information. Note: The logging feature only
-54- 4-5, 4-7, 6-7, <TagPriority : 0-7>, any} | vid {<Vid : 1-4095>, any} <AceId : 1-512> ACE ID action Access li
-55- access-list rate-limiter <RateLimiterList : 1~16> pps <PpsRate : 0-131071> <RateLimiterList : 1~16> Rate limiter ID
-56- aggregation mode dmac | ip | port | smac dmac Destination MAC affects the distribution ip IP address affects the distribution
-57- distribution only. Switch# configure terminal Switch (config)# access-list rate-limiter pps 100 4.2.20 banner Command: banner <LINE>
-58- Default: N/A Usage Guide: To configure login banner-text. Example: To configure login banner-text with word “wwwwwwwwww”. Switch# config
-59- Press ENTER to get started wwwwwwwwww Username: admin Password: 4.2.23 banner motd Command: banner motd <LINE> <LINE>
-5- 4.2.48.6 access-list rate-limiter...
-60- 4.2.24 clock summer-time Command: clock summer-time <WORD> date <Monthstart: 1-12> <Daystart: 1-31> <Yearstart: 1-12&g
-61- default access-list rate-limiter <RateLimiterId : 1-16> <RateLimiterId : 1-16> Rate limiter ID Default: 0 Usage Guide:
-62- Example: To set the Re-authenticated Period (777 seconds). Switch# configure terminal Switch (config)# dot1x authentication timer re-aut
-63- Switch (config)# dot1x guest-vlan 2 4.2.31 dot1x guest-vlan supplicant Command: dot1x guest-vlan supplicant supplicant The switch remem
-64- 4.2.33 dot1x system-auth-control Command: dot1x system-auth-control Default: Disable Usage Guide: To enable 802.1X service for Network
-65- Default: 30 Usage Guide: To configure 802.1X EPOAL timeout for Network Access Server Example: To configure 802.1X EPOAL timeout (45 seco
-66- Command: enable password level <1-15> <WORD> <1-15> Leve l number <WORD> The UNENCRYPTED (cleartext) pa
-67- To configure enable password(cisco) to encrypted secret in the system configurations and specific level(15) for user Switch# configure termin
-68- exit Default: N/A Usage Guide: To e x it configure terminal mode. Example: To e x it configure terminal mode. Switch# configure term
-69- 4.2.42 green-ethernet led on-event Command: green-ethernet led on-event error | link-change <0-65535> error Set LEDs inten
-6- 4.2.48.47 lldp med transmit-tlv ...
-70- Command: gvrp max-vlans <1-4095> Default: 20 Usage Guide: To configure how many VLANs will be in GVRP. Example: To configure 20
-71- Switch# configure terminal Switch (config)# gvrp time join-time 5 leave-all-time 1200 leave-time 150 4.2.46 help Command: help Defaul
-72- N/A Usage Guide: To configure switch’s hostname. Example: To configure switch’s hostname with “nsswitch” Switch# configure terminal Switch
-73- Permit Usage Guide: To configure Permit for the ACL action. Example: To configure Permit ACL action for the GigabitEthernet X/X. Switch# co
-74- To enable Logging function for the ACL. Example: To enable ACL Logging function for the GigabitEthernet X/X. Switch# configure terminal Swit
-75- Enable Usage Guide: To enable Port-state function for the ACL. Example: To configure ACL Port-state function for the GigabitEthernet X/X.
-76- Disable Usage Guide: To redirect frames to specific Port. Example: To redirect GigabitEthernet X/X frames to GigabitEthernet 1/2. Switch#
-77- N/A Usage Guide: To configure aggregation group. Example: To configure aggregation group 7 for the GigabitEthernet X/X. Switch# configure
-78- Example: To run “show aaa” in configure terminal mode. Switch# configure terminal Switch (config)# interface GigabitEthernet X/X Switch (conf
-79- mac-based Switch authenticates on behalf of the client multi Multiple Host 802.1X Authentication sing
-7- 4.2.48.88 qos dscp-remark...
-80- dot1x radius-vlan dot1x IEEE Standard for port-based Network Access Control radius-vlan Enables/disables per-p
-81- duplex auto | full | half duplex Interface duplex auto Auto negotiation of duplex mode. full Forced full duplex. ha
-82- 4.2.48.19 excessive-restart Command: excessive-restart excessive-restart Restart backof f al gorithm after 1 6 coll isions (N o e xce
-83- 4.2.48.21 flowcontrol Command: flowcontrol off | on flowcontrol Traffic flow control. off Disable flow control. on
-84- 4.2.48.23 green-ethernet short-reach(GG) Command: green-ethernet short-reach green-ethernet Green ethernet (Power reduction)
-85- 4.2.48.25 gvrp leave-request vlan(GG) Command: gvrp leave-request vlan <vlan_list> gvrp Enable GVRP on port(s) l
-86- Switch (config-if) # ip arp inspection check-vlan 4.2.48.27 ip arp inspection logging Command: ip arp inspection logging all | deny | permi
-87- To configure Trusted into ARP inspection for GigabitEthernet X/X Switch# configure terminal Switch (config)# interface GigabitEthernet X/X Sw
-88- Switch# configure terminal Switch (config)# interface GigabitEthernet X/X Switch (config-if) # ip igmp snooping filter 1 4.2.48.31 ip igmp s
-89- Switch (config)# interface GigabitEthernet X/X Switch (config-if) # ip igmp snooping max-groups 5 4.2.48.33 ip igmp snooping mrouter Command
-8- 4.2.48.129 switchport vlan mapping ...
-90- Switch (config)# interface GigabitEthernet X/X Switch (config-if) # ip verify source 4.2.48.35 ip verify source limit Command: ip verify so
-91- Switch (config)# interface GigabitEthernet X/X Switch (config-if) # ipv6 mld snooping filter 1 4.2.48.37 ipv6 mld snooping immediate-leave C
-92- Switch (config-if) # ipv6 mld snooping max-groups 5 4.2.48.39 ipv6 mld snooping mrouter Command: ipv6 mld snooping mrouter [ automatic | fi
-93- Switch# configure terminal Switch (config)# interface GigabitEthernet X/X Switch (config-if) # lacp 4.2.48.41 lacp key Command: lacp key &
-94- To configure LACP port-priority (555) for GigabitEthernet X/X Switch# configure terminal Switch (config)# interface GigabitEthernet X/X Switc
-95- Fast Usage Guide: To configure LACP timeout type for specific interface Example: To enable LACP timeout type (slow) for GigabitEthernet X/X
-96- policy-list Assignment of policies <v_range_list> Policies to assign to the interface Default: N/A Usage Guide: To apply ME
-97- 4.2.48.48 lldp receive Command: lldp receive lldp LLDP configurations receive Enab le/Disable decoding of received LLDP fr
-98- 4.2.48.50 lldp tlv-select port-description Command: lldp tlv-select port-description lldp LLDP configurations tlv-select To tr
-99- Switch (config-if) # lldp tlv-select system-capabilities 4.2.48.52 lldp tlv-select system-description Command: lldp tlv-select system-descrip