IFS NS3552-8P-2S AND NS3550-2T-8S User Manual
326
4.17 Loop Protection
This page allows the user to inspect the current Loop Protection configurations, and possibly change them as well.
4.17.1 Configuration
This page allows the user to inspect the current Loop Protection configurations,
Figure 4-17-1: Loop Protection Configuration Page Screenshot
The page includes the following fields:
General Settings:
Object
Description
Enable Loop
Protection
Controls whether loop protections is enabled (as a whole).
Transmission Time
The interval between each loop protection PDU sent on each port. Valid values
are 1 to 10 seconds.
Shutdown Time
The period (in seconds) for which a port will be kept disabled in the event of a loop
is detected (and the port action shuts down the port). Valid values are 0 to 604800
seconds (7 days). A value of zero will keep a port disabled (until next device
restart).