Interlogix NS3550-2T-8S User Manual Manual de usuario Pagina 145

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 631
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 144
IFS NS3552-8P-2S AND NS3550-2T-8S User Manual
145
4.6.10.3 Port Isolate
The diagram shows how the Managed Switch handles isolate and promiscuous ports, and the each PC is not able to access each
other PCs of each isolate port. But they all need to access with the same server/AP/Printer. The screen in Figure 4-6-14 appears.
This section will show you how to configure the port for the server that could be accessed by each isolate port.
Figure 4-6-14: The Port Isolate VLAN Diagram
Setup steps
1. Assign Port Mode
Set Port-1~Port-4 in Isolate port.
Set Port5 and Port-6 are in Promiscuous port. The screen in Figure 4-6-15 appears.
Vista de pagina 144
1 2 ... 140 141 142 143 144 145 146 147 148 149 150 ... 630 631

Comentarios a estos manuales

Sin comentarios