Concord 4 User Manual 31
Event code Description
999 System is in alarm condition.
If a user arms the system to Level 3 (away), the pager will report that the system
was armed to Level 3. However, if the system is armed from a hardwired
touchpad and the user does not exit the premises, the arming level will revert to
Level 2 (stay) without notifying the pager.
The sensor or user number (Table 4 below) identifies who or what is causing the
event.
Table 4: Pager sensor or user number
Code Description
000 System event not caused by sensor or user.
001 to 096 Sensor numbers (1 to 96 for Concord 4; 1 to 32 for Concord
Express V4).
600 to 829 User codes used (0 to 229 for Concord 4; 00 to 15 for Concord
Express V4).
830 to 835 Partition master code used (Concord 4 systems only).
846 System master code used.
847 Installer code used.
848 Dealer code used.
850 Quick arm used.
851 Keyswitch sensor used.
852 System armed itself because it is being serviced or powered-up.
The account number identifies where (which partition) the event is occurring. The
account number code indicates the last four digits of your account number.
Streamlining the page report
You can choose to have the four account number digits reported with every
page, or to exclude them. Each partition has its own account number, so seeing
the digits is useful if multiple partitions are reporting to one pager. Ask your
dealer or installer if you would like the streamline feature turned on.
Time schedules
Time schedules are windows of time defined by a start time, a stop time, and the
day of the week these times are effective. You can create up to 16 time
schedules for setting up the following system features: