Simon XT Installation Manual 19
Function
Default setting
Required setting
Call waiting
Off
On if reporting to central station and customer has
call waiting service
Exit extension
On
On
Swinger shutdown
On (one trip)
On (one trip)
Fire alarm verify
Off
On
Duress/panic code
Disabled
Disabled
Cross zone
Disabled
Disabled for zones with high probability of false
alarms.
Table 8 below describes nonprogrammable (hard-coded) system operation, as
required to meet ANSI-SIA CP-01, and is provided only for your reference.
Table 8: Nonprogrammable (hard coded) system operation
Function
Operation
Silent exit
All annunciators disabled
Remote arming exit time and progress
annunciation
All annunciators enabled
Abort annunciation
Enabled
Cancel report annunciation
Enabled
Recent closing
Enabled (two minute window)
Exit error
Enabled
Restoration of power
Panel resumes operation in same arming
state and disregards alarm signals from
sensors for the first 60 seconds after power
restoration
Cancel alarm
Enter code only.
Central station reporting
The panel has been tested with the following central station receivers using SIA
and Contact ID reporting formats:
Note: Before beginning installation, installers must verify compatibility with the
following central station receivers.
Radionics D6600 central station receiver
Sur-Gard central station receiver with models SG-DRL2A and SG-CPM2
CS5000 digital alarm communicator receiver