21-3602E rev1.5 Monitor xL™ Advanced Installation Guide 21
A0xx03
Area Schedule Selections Note: “xx” represents the area number.
Keypad Selections
(left to right on keypad screen) Example:
Default Name Selections Description
000
Area Schedule
00 = none,
01-250 = schedule #
The schedule used to automate this area and enable
all scheduling features (if applicable).
0
Out of Schedule Open
0=30min, 1= 2-hours
2 = Unlimited
Allowed duration for Disarming outside of schedule.
0
In Schedule Open
0=30min, 1= 2-
hours, 2 = Unlimited
Allowed duration for Disarming within the schedule.
0
Work Late Time
Extension
0=30 min, 1=1hr,
2=1.5hr, 3=2hr,
4=3hr, 5=4hr, 6=6hr,
7=8hr
The duration that the scheduled closing time will be
extended when a work-late button is pressed at an
e.g. area’s keypad.
(no)
Limit to Midnight
(yes) (no)
Limit 'work-late' to not extend beyond midnight.
(no)
Transmit Fail to Close
(yes) (no)
If an area is not armed at the end of its schedule, a fail to
close is transmitted to the monitoring station.
(no)
Auto Arm on Fail to
Close
(yes) (no)
‘Stay-on-fail-to-exit’ and ‘AutoArm-on-fail-to-close’ cannot be
(yes) simultaneously.
(no)
Allow Un-authorized
Open
(yes) (no)
Authority needed to disarm after-hours. Whether or
not users without
'24-hr' authority will be able to
disarm this area outside of its
open/close schedule,
and/or adjust the area closing time (i.e., 'worklate')
after their
schedule has expired. (For a non-
scheduled area, this feature does not apply, since only
'Disarm' authority would be required.)
(no)
Auto Disarm to Off
Always
(yes) (no)
A0xx04 Automation
Keypad Selections (left to right on keypad screen)
Note: “xx” represents the area number.
Default Name Selections Description
000
Automatic Stay-Mode
Schedule #
00 = none,
01-250 = schedule #
0
Automatic Stay-Mode
0 = None
1 = Standard ‘Auto Stay Mode’ (Non-
secure)
2 = Secure ‘Auto Stay Mode’
(Requires Area On before next
automatic Stay To Off)
0
Auto Disarm on Valid
Token In Area
Schedule
NOTE: This feature is only
available with the addition of the
Feature Expansion Board.
0 = None, 1= Follow user authority
2 = Force to Stay 3 = Force to Off
The area will automatically disarm
when a user/entrant is granted access
in the area schedule.
0
Auto Disarm on Valid
Token Out of Area
Schedule
NOTE: This feature
is only available with the addition
of the Feature Expansion Board.
0 = None, 1= Follow user authority
2 = Force to Stay, 3 = Force to Off
The area will automatically disarm
when a user/entrant is granted access
out of the area schedule.
000·
0
·
0
·
0
··
Save A00103