4.2.205 sflow timeout
Command:
sflow timeout <timeout>
sflow Statistics flow
timeout Receiver timeout measured in seconds. The switch decrements the timeout once per second, and as long as it
is non-zero, the receiver receives samples. Once the ti meout reaches 0, the receiv er and all its configuration
is reset to defaults.
<timeout: 0-2147483647> Number of seconds
Default:
None
Usage Guide:
To configure the Collector timeout of sFlow
Example:
To configure the Collector timeout (555 seconds) of sFlow
Switch# configure terminal
Switch (config)# sflow timeout 555
4.2.206 sfp temperature-threshold
Command:
sfp temperature-threshold <0-100>
sfp temperature-threshold Set a lower high temperature threshold for the secondary
temperature alarm in degrees C.
<0-100> Specifies the new threshold temperature.
Default:
None
Usage Guide:
To configure the SFP temperature-threshold of sFlow
Example:
To configure the SFP temperature-threshold (55 degrees C) of sFlow
Switch# configure terminal
Switch (config)# sfp temperature-threshold 55