Chapter 5: Web-Based Management
GE-DSH-73/DSH-82 and DSH-82-PoE User Manual 55
Figure 5-11: Syslog Configuration interface
This page includes the following fields:
Object Description
Syslog Client Mode:
Select the system log mode—Client Only, Server Only, or Both.
Client Only: the system event log will only be sent to this interface of
the switch
Server Only: the system log will only be sent to the remote system
log server with its IP assigned.
Both: the system event log will be sent to the remote server and this
interface.
System Log Server IP
Address:
When the ‘Syslog Mode’ item is set as Server Only/Both, the user
has to assign the system log server IP address to which the log will
be sent.